Skip to content
Datasheet

Fiberglass round tube 32×3 mm

Dimensions, section properties computed from the geometry, allowable loads by span and EN 13706 E23 mechanical data for the CHS 32×3 pultruded profile.

Model
CHS 32×3
EN 13706 grade
E23
Published mass
0.4 kg/m
Section area
273.3 mm²
Request a quoteAsk the AI assistantWhatsApp

Start with your name and email. Product details and drawings can follow.

Cross-section and section properties

FIG. 1 CHS ⌀32×3Drawn to scale

≈ 1.260 × 0.118 in, for reference only; the metric dimensions govern.

Dimensions of CHS 32×3
Outside diameter (OD)32 mm
Wall thickness (t)3 mm
Mass per meter (published)0.4 kg/m
Section properties of CHS 32×3, calculated from the geometry
Section property (calculated)Value
Cross-section area A273.3 mm²
Moment of inertia Ix2.904 cm⁴
Moment of inertia Iy2.904 cm⁴
Section modulus Sx1.815 cm³
Section modulus Sy1.815 cm³
Radius of gyration rx10.31 mm
Radius of gyration ry10.31 mm
Torsion constant J5.808 cm⁴
Mass per meter (calculated)0.519 kg/m

Derived from the cross-section geometry by polygon integration. The published mass per meter is the catalog value; the calculated figure is a geometric cross-check. Because the modulus of FRP is about a tenth of steel's, deflection usually governs, so check spans in the profile calculator. For a planning budget per meter, enter these dimensions in the price estimator.

A dimensioned cross-section in DXF, free and without a login. It opens in AutoCAD, DraftSight, LibreCAD and other CAD packages.

What a 32×3 mm fiberglass round tube carries

Allowable service uniform load for CHS 32×3 as a simply supported beam, from the published FRP span tables. Design basis: EN 13706 Grade E23 (E-glass pultruded); LRFD, ASCE/SEI 74-23 (φ = 0.65, λ = 0.8 for occupancy live load, γ_Q = 1.6); Outdoor exposed (0.85 on strengths); deflection limit L/250 at service load (Timoshenko shear deflection included). Typical uses for this family: handrails, cross-members and light spanning members.
Allowable uniform load for CHS 32×3 by simply supported span
Span (m)Allowable UDL (kN/m)≈ lb/ftGoverning check
10.2013.9deflection
1.50.064.1deflection

Spans where the allowable load falls below 0.05 kN/m are omitted. Point loads, connections, lateral restraint and other exposures need their own check: open this section in the calculator or compare every size in the span tables.

Mechanical and physical properties

Laminate E23 · Isophthalic polyester (general purpose) / E-glass. Test methods are those of EN 13706 and the ISO and ASTM methods it cites.

Internal catalog reference: f1-rt-002 (website reference, not a manufacturer SKU). Material dataset: E23-ISO. Revision: catalog-05fc2fc34578.

The design manual provides general-purpose E23 laminate and sizing references. No public test report is mapped to this exact section and formulation; this is not configuration certification or confirmed availability. Published catalog mass for the default dataset; confirm finished-product mass.

The methods below identify measurement standards, not proof that this section was tested. Confirm manufacturing, required performance and the applicable report before specification.

Check evidence for this configuration
Mechanical and physical properties of the CHS 32×3 laminate
PropertyValueTest method
Tensile modulus (longitudinal)23 GPaEN ISO 527-4
Tensile modulus (transverse)7 GPaEN ISO 527-4
Tensile strength (longitudinal)240 MPaEN ISO 527-4
Tensile strength (transverse)50 MPaEN ISO 527-4
Flexural strength (longitudinal)240 MPaEN ISO 14125
Flexural strength (transverse)100 MPaEN ISO 14125
Interlaminar shear strength (ILSS)30 MPaEN ISO 14130
Pin-bearing strength (longitudinal)150 MPaEN 13706-2 Annex E
Pin-bearing strength (transverse)70 MPaEN 13706-2 Annex E
Compressive strength (longitudinal)240 MPaEN ISO 604
Barcol hardness45ASTM D2583
Water absorption (24 h)0.6 %EN ISO 62
Resin:
Isophthalic unsaturated polyester
Glass content:
65–70% by weight
Density:
1.9 g/cm³
Grade:
E23
Fire:
Standard grade — not fire-retardant (specify an FR grade for ASTM E84 Class 1)

Data basis: F1-published general-purpose laminate (FRP Profile Design Manual DOC-PF-2026-EN Rev. B); ILSS 30 MPa published above the EN 13706 minimum of 25 MPa; transverse values are EN 13706-3 Table 1 grade minimums. Standard isophthalic polyester is not fire-retardant — for ASTM E84 Class 1 specify the FR-E23 grade. Compressive strength, Barcol hardness and water absorption are not specified by EN 13706 — the figures shown are typical industry values for this resin system, pending F1 certified test data; request certified values before final design.

Standards: EN 13706 Grade E23.

Values marked “Verify before release” are pending certified test data and are never estimated. Request batch-traceable certified data through the quote form before final design.

CHS 32×3: common questions

How much does a fiberglass round tube 32×3 mm weigh?

The published mass is 0.4 kg per meter (about 0.27 lb/ft), so a standard 6 m length weighs about 2.4 kg.

What load can a 32×3 mm fiberglass round tube carry?

On the published design basis (EN 13706 E23, LRFD to ASCE/SEI 74-23, outdoor exposure, L/250 deflection with shear deformation), the allowable service uniform load is about 0.20 kN/m over a simply supported 1 m span and 0.06 kN/m over 1.5 m (deflection governs at 1.5 m). Check point loads, connections and your own exposure in the calculator before release.

Is there a CAD drawing for CHS 32×3?

Yes. A dimensioned DXF cross-section is a free download on this page, with no login. It opens in AutoCAD, DraftSight, LibreCAD and other CAD packages.

What is the lead time for CHS 32×3?

CHS 32×3 is a catalog section in 6 m standard lengths. Catalog sections ship in 2–4 weeks. Catalog dimensions identify standard section options, not live inventory. Confirm tooling, material, quantity and production timing in the quotation.

Need a quote for CHS 32×3?

Send the dimensions, quantity, service conditions and destination. We reply within one business day.

Get a quoteWhatsApp