Test report · SHIN2608002943CM01_EN
E40 evidence — SGS full-section test, 40.8 GPa
SGS SHIN2608002943CM01_EN, issued 2026-09-07: full-section test to EN 13706-2 Annex D, 40.8 GPa average from three specimens. Page 1 specification 60605; page 3 specimen 2160 × 90 × 90 mm. These size identifiers need clarification before size-specific qualification. Results apply only to the tested samples; conclusion N/A, with an internal-reference use note. Supports the reported 40 GPa-class result, not EN 13706 E40 certification or a design allowable.
Test report · SHIN2608002943CM02_EN
E40 evidence — SGS full-section test, 41.5 GPa
SGS SHIN2608002943CM02_EN, issued 2026-09-07: full-section test to EN 13706-2 Annex D, 41.5 GPa average from three specimens. Page 1 specification 90905; page 3 specimen 1440 × 60 × 60 mm. These size identifiers need clarification before size-specific qualification. Results apply only to the tested samples; conclusion N/A, with an internal-reference use note. Supports the reported 40 GPa-class result, not EN 13706 E40 certification or a design allowable.
Component certificate · PHI 2491wi03
90-series GFRP window component certificate
PHI 2491wi03 names Chongqing Xianju New Material Co., Ltd. and Fengdu Passive GFRP 90 Series. The stated configuration is cool-temperate, efficiency class phB, Uw 0.78 W/(m²·K) with Ug 0.70; valid until 31 December 2026. It is not Arctic-climate, PHIUS or blanket F1-window certification. Confirm the original and proposed configuration.
Test report · Intertek 240821010SHF-001
Turn-and-tilt GFRP window test report
AS 2047 testing of the identified window specimen. Match dimensions, glazing, hardware, pressure and test conditions before using the results.
Test report · Intertek 240821010SHF-002
Lift-sliding GFRP door test report
Historical 140 Series Lift-Sliding Door specimen, 3000 × 2400 mm, as named in Intertek 240821010SHF-002. The original report is preserved. It does not automatically cover the current 140 Series Compression-Seal Sliding Door; configuration equivalence requires technical verification.
Technical reference · DOC-PF-2026-EN Rev. B
FRP profile design manual
Revision B (October 2026), generated from the website's catalog, laminate and design-basis data: EN 13706 E23 laminate values beside the grade minimums, section properties of all 114 catalog sizes, allowable uniform loads to the published LRFD screening basis, application guides, durability stated by resin formulation, fabrication and inspection. A preliminary-sizing reference, not a project approval or batch certificate; it supersedes the withdrawn Rev. A.
Technical reference · PU-GF data sheet
PU-GF pultruded profile mechanical data
The material system and methods identified in the sheet. Confirm whether each value is typical, measured or a design value before applying it to another laminate or section.
Technical reference · GFRP and CFRP laminate data sheet
Wind-energy pultruded laminate data
The tested laminate and reinforcement described in the document. Fatigue and fiber-content results apply to the stated specimens, not all blade or spar-cap designs.
Technical reference · Window and door catalog
Pultruded FRP window and door catalog
Nine-series purchasing reference: 50, 55, 60, 65, 70, 80, 90 casement, 90 sliding and 140 compression-seal sliding. Covers separate profile and finished-unit procurement paths, updated profile codes and configuration-specific evidence boundaries. Confirm drawings, glazing, hardware and supply scope at quotation.
Test report · Wuxi / CPVT 2025DACS20319
PV module frame material test report
Composite PV module frame in all-weather modified resin: mean tensile strength 1,310 MPa, flexural strength 1,060 MPa, flexural modulus 48.0 GPa, HDT above 290 °C and flammability V-1, with UV, damp-heat, humidity-freeze, thermal-cycle, salt-mist and ammonia exposure results. The report gives measurements without a pass/fail conclusion, and its salt-mist cycle count and duration are inconsistent.
Test report · TÜV Rheinland CN24KZ3A 002
PV frame coating test report: Jotun Jota Solar CL
GFF-series PV frames with Jotun Jota Solar CL coating, tested to the coating-change clauses of 2 PfG 2923/11.22 with a Pass result stated on the cover; other clauses refer to CN24KZ3A 001. TÜV Rheinland does not permit reproduction in extracts without its approval, and the report does not authorize a test mark.
Test report · TÜV Rheinland CN24KZ3A 003
PV frame coating test report: B9986S polyester
GFF-series PV frames with B9986S polyester coating, tested to the coating-change clauses of 2 PfG 2923/11.22 with a Pass result stated on the cover; other clauses refer to CN24KZ3A 001. TÜV Rheinland does not permit reproduction in extracts without its approval, and the report does not authorize a test mark.
Test report · SGS GZMR260702529004
Composite profile material flammability test report
Composite profile material E-TS-AB: V-0 to UL 94-2023 Rev.2-2024 Section 8 at 10.1 mm thickness. The result does not establish V-0 for thin-wall PV frames, and SGS marks the report for internal reference.