Skip to content
F1-THERM· Finished units

Finished fiberglass windows & doors

F1 Composite supplies finished windows and doors built with pultruded FRP profiles. This route is for project buyers who need assembled units rather than lineals. Frame series, glazing, hardware, accessories and delivery scope are confirmed against the opening schedule.

FIG. 1 80 series tilt-and-turn
Corner section of an 80-series tilt-and-turn FRP window
Systems
9 series
Frame depth
50–140 mm
Test reports
AS 2047
RFQ template
Window schedule

Last updated

Request a finished-unit quoteDownload the schedule templateWhatsApp

Start with a sample, a budget estimate, a technical review or a formal quotation.

A complete configuration you can approve

Begin with the opening schedule and required operation. Frame depth alone does not determine thermal, air, water or structural performance. The dimensions, glass build-up, seals, hardware and installation detail together define the offered unit.

Who buys this
Building-project procurement teams, contractors and window distributors
Supply scope
Project-specified window and door units with the agreed glazing, hardware and accessories
Fabricating locally? Window and door profiles
FIG. 2 140 series sliding door
Corner section of a 140-series FRP sliding door frame with triple glazing

Compare nine window & door systems 9 systems

Start with the opening you need, then review the matching profile set. The 90 casement and 90 sliding systems are distinct; the 140 series uses compression-seal sliding operation.

9 systems shown · compare up to three

50 Series Window System corner assembly

50 mm frame · Casement / tilt-and-turn

50 Series Window System

50 mm system for inward-opening and outward-opening configurations. Match glass, hardware and interfaces as a set.

Quote units
Sections & configuration: 50 Series Window System

Catalog opening references: Inward-opening · Outward-opening · Tilt-and-turn · Top-hung outward · Tilt-in. Review the proposed size and hardware before ordering.

Reference load-bearing wall
2.5 mm
Catalog leaf-load reference
65 kg*

*Configuration-dependent catalog information, not an approved operating limit. Confirm the drawing, hardware, glazing and verification scope.

50 Series Window System source-catalog profile cross-sections in current code-list order; reference geometry only, not dimensioned production drawings
Section outlines follow the code list below, from left to right. Request dimensioned drawings before fabrication.
  • GF0701Window frame
  • GF0702Mullion
  • GF0703Window sash
Discuss a sample unit
55 Series Window & Door System corner assembly

55 mm frame · Casement / tilt-and-turn

55 Series Window & Door System

55 mm system for inward-opening and outward-opening configurations. Match glass, hardware and interfaces as a set.

Quote units
Sections & configuration: 55 Series Window & Door System

Catalog opening references: Inward-opening · Outward-opening · Tilt-and-turn · Top-hung outward · Tilt-in · Double-leaf · Inward-opening door · Outward-opening door. Review the proposed size and hardware before ordering.

Reference load-bearing wall
2.7 mm
Catalog leaf-load reference
70 kg*

*Configuration-dependent catalog information, not an approved operating limit. Confirm the drawing, hardware, glazing and verification scope.

55 Series Window & Door System source-catalog profile cross-sections in current code-list order; reference geometry only, not dimensioned production drawings
Section outlines follow the code list below, from left to right. Request dimensioned drawings before fabrication.
  • GF0801Window frame
  • GF0802Mullion
  • GF0803Window sash
  • GF0804Adapter frame
Discuss a sample unit
60 Series Window System corner assembly

60 mm frame · Casement / tilt-and-turn

60 Series Window System

60 mm system for inward-opening and outward-opening configurations. Match glass, hardware and interfaces as a set.

Quote units
Sections & configuration: 60 Series Window System

Catalog opening references: Inward-opening · Outward-opening · Tilt-and-turn · Top-hung outward · Tilt-in. Review the proposed size and hardware before ordering.

Reference load-bearing wall
2.5 mm
Catalog leaf-load reference
75 kg*

*Configuration-dependent catalog information, not an approved operating limit. Confirm the drawing, hardware, glazing and verification scope.

60 Series Window System source-catalog profile cross-sections in current code-list order; reference geometry only, not dimensioned production drawings
Section outlines follow the code list below, from left to right. Request dimensioned drawings before fabrication.
  • CP6001Window frame
  • CP6002Outward-opening window sash
  • CP6003Mullion
  • CP6004Adapter frame
  • CP6005Outward-opening door leaf
  • CP6006Door false mullion
Discuss a sample unit
65 Series Window System corner assembly

65 mm frame · Casement / tilt-and-turn

65 Series Window System

65 mm system for inward-opening and outward-opening configurations. Match glass, hardware and interfaces as a set.

Quote units
Sections & configuration: 65 Series Window System

Catalog opening references: Inward-opening · Outward-opening · Tilt-and-turn · Top-hung outward · Tilt-in. Review the proposed size and hardware before ordering.

Reference load-bearing wall
3 mm
Catalog leaf-load reference
110 kg*

*Configuration-dependent catalog information, not an approved operating limit. Confirm the drawing, hardware, glazing and verification scope.

65 Series Window System source-catalog profile cross-sections in current code-list order; reference geometry only, not dimensioned production drawings
Section outlines follow the code list below, from left to right. Request dimensioned drawings before fabrication.
  • GF0201Window frame
  • GF0202Mullion
  • GF0203Inward-opening window sash
  • GF0204Outward-opening adapter frame
  • GF0205Outward-opening window sash
  • GF0206Outward-opening window frame
Discuss a sample unit
70 Series Window & Door System corner assembly

70 mm frame · Casement / tilt-and-turn

70 Series Window & Door System

70 mm system for inward-opening and outward-opening configurations. Match glass, hardware and interfaces as a set.

Quote units
Sections & configuration: 70 Series Window & Door System

Catalog opening references: Inward-opening · Outward-opening · Tilt-and-turn · Top-hung outward · Tilt-in · Double-leaf · Inward-opening door · Outward-opening door. Review the proposed size and hardware before ordering.

Reference load-bearing wall
3 mm
Catalog leaf-load reference
120 kg*

*Configuration-dependent catalog information, not an approved operating limit. Confirm the drawing, hardware, glazing and verification scope.

70 Series Window & Door System source-catalog profile cross-sections in current code-list order; reference geometry only, not dimensioned production drawings
Section outlines follow the code list below, from left to right. Request dimensioned drawings before fabrication.
  • GF0301Window frame
  • GF0302Mullion
  • GF0303Inward-opening window sash
  • GF0304Outward-opening adapter frame
  • GF0305Outward-opening window sash
  • GF0306Outward-opening window frame
Discuss a sample unit
80 Series Window System corner assembly

80 mm frame · Casement / tilt-and-turn

80 Series Window System

80 mm system for inward-opening and tilt-and-turn configurations. Match glass, hardware and interfaces as a set.

Quote units
Sections & configuration: 80 Series Window System

Catalog opening references: Inward-opening · Tilt-and-turn. Review the proposed size and hardware before ordering.

Reference load-bearing wall
3 mm
Catalog leaf-load reference
130 kg*

*Configuration-dependent catalog information, not an approved operating limit. Confirm the drawing, hardware, glazing and verification scope.

80 Series Window System source-catalog profile cross-sections in current code-list order; reference geometry only, not dimensioned production drawings
Section outlines follow the code list below, from left to right. Request dimensioned drawings before fabrication.
  • GF0501Window frame
  • GF0502Mullion
  • GF0503Inward-opening window sash
Discuss a sample unit
90 Series Casement / Tilt-and-Turn System corner assembly

90 mm frame · Casement / tilt-and-turn

90 Series Casement / Tilt-and-Turn System

90 mm system for inward-opening and tilt-and-turn configurations. Match glass, hardware and interfaces as a set.

Quote units
Sections & configuration: 90 Series Casement / Tilt-and-Turn System

Catalog opening references: Inward-opening · Tilt-and-turn · Double-leaf · Inward-opening door · Outward-opening door. Review the proposed size and hardware before ordering.

Reference load-bearing wall
3 mm
Catalog leaf-load reference
130 kg*

*Configuration-dependent catalog information, not an approved operating limit. Confirm the drawing, hardware, glazing and verification scope.

90 Series Casement / Tilt-and-Turn System source-catalog profile cross-sections in current code-list order; reference geometry only, not dimensioned production drawings
Section outlines follow the code list below, from left to right. Request dimensioned drawings before fabrication.
  • GF0601Window frame
  • GF0602Mullion
  • GF0603Inward-opening window sash
Discuss a sample unit
90 Series Sliding Window System corner assembly

90 mm frame · Sliding window

90 Series Sliding Window System

A separate sliding system, with CP001–CP005 profile references. Request current drawings before choosing individual sections.

Quote units
Sections & configuration: 90 Series Sliding Window System

Catalog opening references: Sliding. Review the proposed size and hardware before ordering.

Reference load-bearing wall
3 mm
Catalog leaf-load reference
120 kg*

*Configuration-dependent catalog information, not an approved operating limit. Confirm the drawing, hardware, glazing and verification scope.

  • CP001Section details on request
  • CP002Section details on request
  • CP003Section details on request
  • CP004Section details on request
  • CP005Section details on request

Ask for the current section drawings and component mapping for CP001–CP005. The codes alone do not confirm a mating profile set.

Discuss a sample unit
140 Series Compression-Seal Sliding Door corner assembly

140 mm frame · Sliding door

140 Series Compression-Seal Sliding Door

Side-pressure sealing for sliding doors. Confirm the panel arrangement, hardware and threshold for your opening.

Quote units
Sections & configuration: 140 Series Compression-Seal Sliding Door

Catalog opening references: Sliding with side-pressure compression seal. Review the proposed size and hardware before ordering.

Reference load-bearing wall
3 mm
Catalog leaf-load reference
200 kg*

*Configuration-dependent catalog information, not an approved operating limit. Confirm the drawing, hardware, glazing and verification scope.

140 Series Compression-Seal Sliding Door source-catalog profile cross-sections in current code-list order; reference geometry only, not dimensioned production drawings
Section outlines follow the code list below, from left to right. Request dimensioned drawings before fabrication.
  • CP006Outer frame
  • CP007Former inward-opening mullion - assembly to confirm
  • CP008Sliding mullion
  • CP009Sliding inner sash
  • CP010Former inward-opening inner sash - assembly to confirm
  • CP011Outer-frame closure

CP006–CP011 identify the compression-seal series. Confirm current assembly drawings; a historical lift-sliding test report does not automatically cover this system.

Discuss a sample unit

Show us how each opening should work

Use the operation diagrams to describe each opening. Mark left or right handing and whether drawings are viewed from inside or outside, then confirm the configurations available in the chosen series.

Static diagrams shown to respect your reduced-motion preference.

  • Casement

    Side-hung; full opening and strong compression sealing.

  • Awning

    Top-hung; ventilates while helping shed light rain.

  • Tilt & turn

    Tilt ventilation plus inward opening for access and cleaning.

  • Fixed light

    Fixed window combination; available series and glazing require project review.

  • 90 series sliding

    Horizontal sliding window; confirm the 90 sliding configuration.

  • PLAN VIEW · SCHEMATICSeal compression across track

    140 compression-seal sliding door

    Schematic: slide horizontally, then press toward the seal when closing. Hardware geometry requires confirmation.

From specification to project delivery

Open your situation to see what to share, what we review with you and what to settle before moving ahead.
Finished unitsWindow importers & dealersWhat do we need for a sample order and ongoing sales?

Review market needs → choose configurations → check documents → evaluate a sample → place a trial order → replenish & support

You share
Market, opening types, target configurations, sample needs and local service arrangements.
We review with you
A finished-unit proposal with glazing, hardware, documents, packing and spare-part scope.
Before moving ahead
Confirm the offered configuration, local installation support and after-sales responsibilities before ordering.
Discuss finished-unit supply
Finished unitsContractors & developersCan the proposed units meet our project and delivery schedule?

Share the window schedule → clarify specifications → compare quotations → approve shop drawings → produce → deliver → install

You share
Window IDs, dimensions and quantities, project location, performance targets, wall details and delivery phases.
We review with you
A quotation by window ID and a list of configuration, document and installation details to confirm.
Before moving ahead
Approve dimensions, handing, glass, hardware and finish before manufacture; agree unloading and installation separately.
Send a window schedule
SpecificationArchitects & facade consultantsWhat can we specify, and which evidence applies?

Explore systems → review sections & details → match performance evidence → discuss the specification → hand over to procurement

You share
Design intent, opening and wall details, performance targets and the project location. Quantities can follow later.
We review with you
Available system information and the scope of documents relevant to the proposed assembly.
Before moving ahead
Distinguish material data, a tested window configuration and the requirements of the installed project.
Discuss a specification

Know what your finished-unit quote includes

Use the scope below when comparing quotations. Availability, quantities, lead time and support are confirmed for the selected specification.
Profile and finished-window quotation scope
Supply itemFinished units
FRP frame, sash and mullion sectionsIncluded in the agreed assembly
Glazing beads, gaskets and connectorsConfirm system and configuration
Glass and operating hardwareSpecify glass build-up and hardware
Cutting, machining and assemblyDefine factory assembly and glazing scope
Evidence and inspectionConfiguration-specific documents and agreed checks
Packing, freight and unloadingConfirm crate dimensions, delivery and unloading
Site installation and after-salesLocal installer and contract-defined service scope
  • Check 1

    Glass

    Specify build-up, safety requirements, coatings, spacer and gas-fill preferences. Whole-window Uw differs from glass-only Ug.

  • Check 2

    Hardware and finish

    Confirm handles, locks, restrictors, access requirements, and interior and exterior colors against the intended opening.

  • Check 3

    Wall interface

    Provide sill, jamb and head details, waterproofing and fixing requirements. Identify the local installer and who approves dimensions.

How finished-unit procurement works

At each stage, agree the information to supply, the next review and the confirmation needed to proceed.
  1. Step 1

    Describe the project

    You provide: Project or dealer use, destination, new-build or replacement and timing.

    We review and return: A supply route and the information needed for selection.

    Confirmation point: Identify project-specific requirements.

  2. Step 2

    Share your schedule

    You provide: Window IDs, width × height, quantity, opening and measurement basis.

    We review and return: A review of missing information and candidate configurations.

    Confirmation point: Distinguish rough opening from finished frame size.

  3. Step 3

    Match the configuration

    You provide: Glass, hardware, finish, wall details and performance targets.

    We review and return: Configuration options and relevant document scope.

    Confirmation point: Match evidence to the offered assembly.

  4. Step 4

    Review the quotation

    You provide: Delivery phases, destination, unloading constraints and spare parts.

    We review and return: Line items by window ID, with supply and delivery boundaries.

    Confirmation point: Agree included and excluded work.

  5. Step 5

    Approve drawings & samples

    You provide: Verified dimensions, handing, finish and shop-drawing comments.

    We review and return: The final window schedule and production specification.

    Confirmation point: Approve configuration before manufacture.

  6. Step 6

    Produce & inspect

    You provide: Agreed acceptance checks and any witness inspection.

    We review and return: The specified inspection records and identification.

    Confirmation point: Factory checks follow the agreed scope.

  7. Step 7

    Pack & deliver

    You provide: Receiving contact, site access and unloading arrangements.

    We review and return: Window-to-crate identification and shipping documents.

    Confirmation point: Check packages and record any damage at receipt.

  8. Step 8

    Install & support

    You provide: Local installation details, inspection findings and service needs.

    We review and return: Agreed installation information, spare parts and after-sales contact.

    Confirmation point: Confirm installation and warranty responsibilities.

A window schedule makes the quote comparable

Use a separate row for every opening configuration. Mark whether dimensions refer to the rough opening or the finished frame, and state the viewing side for handing.

Open the template in Excel or another spreadsheet app. Attach CSV, XLSX, drawings or one ZIP bundle to your RFQ; 4 MB maximum per submission.

Example of a schedule row

Window ID
W01
Size
Width × height + unit
Basis
Rough opening or frame
Operation
Type, handing, viewing side
Configuration
Glass, hardware, finish
Delivery
Quantity + phase

Illustrative format only; this is not a production schedule. Anything left blank is clarified during review.

Evidence that matches your specification

Review each original report against the offered opening type, size, glass, hardware and test conditions. The historical lift-sliding door report does not automatically cover the current 140 compression-seal series. Whole-window Uw differs from glass-only Ug and frame-only Uf; documentation coverage must be checked for the specific configuration.

Material data

Material & section information

Review the identified material system, dimensions and drawing revision. Confirm whether values are typical references or order-specific acceptance criteria.

View material reference

Certificates & reports

Window configuration evidence

Uf is the frame, Ug the glazing and Uw the complete window. The PHI 90-series certificate covers its stated component configuration; it does not certify every size or series.

Review document scope

Your project

Project & installation requirements

Share the destination, project specification and wall interface. Match the offered configuration and installation responsibilities before approving production.

Explore thermal inputs
  • CatalogPDF · 2026 edition

    Nine-Series FRP Window & Door Purchasing Catalog

    Issued by
    F1 Composite
    For
    FRP windows and doors

    Nine-series purchasing reference: 50, 55, 60, 65, 70, 80, 90 casement, 90 sliding and 140 compression-seal sliding. Covers separate profile and finished-unit procurement paths, updated profile codes and configuration-specific evidence boundaries. Confirm drawings, glazing, hardware and supply scope at quotation.

  • TemplateCSV · Editable template

    Finished Window & Door Schedule Template

    Issued by
    F1 Composite
    For
    FRP windows and doors

    For finished units: opening ID, series, dimensions, opening type, glazing, hardware, quantity and delivery requirements.

Packing and delivery

FIG. 3 Window crateSchematic · not to scale
W01
Packing concept. The packing design is agreed for each order.

Plan around each opening and crate

Agree glass protection, crate size and weight, window-to-crate labels, unloading equipment and delivery phases. Check for damage at receipt and keep the window IDs with the installation schedule.

Port delivery, site delivery, unloading and installation are separate scopes. Confirm the local installation team and spare parts before ordering.

Purchasing questions

What is included in a finished-unit quotation?

The quotation identifies the frame, glass, hardware, seals and agreed accessories, together with inspection, packing and delivery terms. Confirm installation materials, site labor and spare parts separately rather than assuming they are included.

Can one U-value be applied to every window size?

No. Whole-window performance changes with frame geometry, window size, glazing and edge details. Request data for the proposed assembly and distinguish whole-window Uw from glass Ug and frame Uf.

What should I send before requesting a price?

Start with the opening schedule, project location, required performance, glazing and hardware preferences. Drawings and quantities allow the unit configuration and documentation requirements to be reviewed before a formal quote.

Bring us your window schedule

Send the window schedule, the glass and hardware you want and the project city. Not ready for a formal quote? Ask for a sample unit, budget pricing or a technical review. We reply within one business day; a formal quotation follows once the specification and delivery are reviewed.

Window schedule
Window IDs, width × height and quantity, and whether sizes are rough opening or frame.
Operation and handing
The opening type of each window, left or right handing and the viewing side of the drawings.
Glass and hardware
Glass build-up, hardware, and the interior and exterior colors.
Project and delivery
Project city, performance targets, wall details, delivery phases and installation scope.
Get a quoteWhatsApp