Skip to content
F1-THERM· Finished windows & doors

Finished fiberglass windows & doors

Eight window formats and three door systems built with glass-fiber-reinforced polyurethane profiles. Explore casement, flush, tilt-and-turn, micro-vent and facade windows, plus insulated entrance, lift-and-slide and side-pressure doors. Configure each unit to your opening schedule.

FIG. 1 114 curtain-wall windowSchematic · not to scale
Complete 114 curtain-wall-style fiberglass window with a broad central light and side opening sections
Illustrative configuration with a broad central light and side opening sections.
Product families
11 systems
Windows
8 formats
Doors
3 formats
Frame material
Glass-fiber / PU

Last updated

Explore the 11 systemsDownload the catalog (PDF)WhatsApp

Have a project schedule? Choose a system below or request a configuration review.

Choose your window or door 11 product families

Compare complete window and door formats for your openings. Open each product for its glazing configurations and catalogue-stated performance, or compare up to three systems.

11 systems shown · 0/3 selected

Select up to three systems to compare. Your selection stays when you filter.

65 Casement Window illustrated catalogue configuration

Window system · Series 65

65 Casement Window

A chambered composite window system for everyday residential use, combining thermal insulation with a practical opening format.

Quote units: 65 Casement Window
Glazing & performance: 65 Casement Window

Whole-window U-value · W/(m²·K)

Glazing build-upU-value
5Low-e + 9A/Ar + 5 + 9A/Ar + 51.6 / 1.5
5Low-e + 9A/Ar + 5Low-e + 9A/Ar + 51.35 / 1.3

Paired U-values and A/Ar notation are retained as listed. The individual conditions are not defined; pairs are not ranges or assigned to a gas fill.

Wind resistance
Class 8
Watertightness
Class 5
Airtightness
Class 7
Airborne sound insulation
>40 dB

Catalogue-stated performance. Test standards, specimen sizes and acoustic rating methods are not specified; no international class conversion is implied. Confirm evidence for your final configuration.

System features

  • Chambered polyurethane composite frame
  • Configurations for new-build and replacement windows
  • Two listed Low-e glazing configurations

Applications

Conventional housing, residential renovation and multi-storey homes.

View catalogue page 4 (PDF): 65 Casement Window
72 Casement Window illustrated catalogue configuration

Window system · Series 72

72 Casement Window

A multi-chamber system for homes with demanding winter insulation requirements. The range includes A, B and C variants.

Quote units: 72 Casement Window
Glazing & performance: 72 Casement Window

Whole-window U-value · W/(m²·K)

Glazing build-upU-value
5 + 12A/Ar + 5 + 12A/Ar + 51.5 / 1.4
5Low-e + 12A/Ar + 5 + 12A/Ar + 51.4 / 1.3
5Low-e + 12A/Ar + 5Low-e + 12A/Ar + 51.3 / 1.2

Paired U-values and A/Ar notation are retained as listed. The individual conditions are not defined; pairs are not ranges or assigned to a gas fill.

Wind resistance
Class 8
Watertightness
Class 5
Airtightness
Class 8
Airborne sound insulation
>40 dB

Catalogue-stated performance. Test standards, specimen sizes and acoustic rating methods are not specified; no international class conversion is implied. Confirm evidence for your final configuration.

System features

  • Multi-chamber profile construction
  • Three listed glazing configurations
  • A / B / C variants; details on request

Applications

Cold-climate housing and residential projects with demanding winter insulation requirements.

View catalogue page 5 (PDF): 72 Casement Window
83 Flush Window illustrated catalogue configuration

Window system · Series 83

83 Flush Window

Flush frame-and-sash styling creates clean sightlines for contemporary residential facades and interiors.

Quote units: 83 Flush Window
Glazing & performance: 83 Flush Window

Whole-window U-value · W/(m²·K)

Glazing build-upU-value
5Low-e + 15A/Ar + 5 + 15A/Ar + 51.4 / 1.3
5Low-e + 15A/Ar + 5Low-e + 15A/Ar + 51.2 / 1.1
5Low-e + 16A/Ar (warm edge) + 5Low-e + 16A/Ar (warm edge) + 51.0 / 0.9

Paired U-values and A/Ar notation are retained as listed. The individual conditions are not defined; pairs are not ranges or assigned to a gas fill.

Wind resistance
Class 8
Watertightness
Class 6
Airtightness
Class 8
Airborne sound insulation
>40 dB

Catalogue-stated performance. Test standards, specimen sizes and acoustic rating methods are not specified; no international class conversion is implied. Confirm evidence for your final configuration.

System features

  • Flush frame-and-sash appearance
  • Choice of surface finishes
  • Warm-edge glazing configuration listed

Applications

Modern homes, large apartments and residential projects with a clean-lined facade.

View catalogue page 6 (PDF): 83 Flush Window
85 Casement Window illustrated catalogue configuration

Window system · Series 85

85 Casement Window

A multiple-seal window system with low reported whole-window U-values for buildings with demanding thermal targets.

Quote units: 85 Casement Window
Glazing & performance: 85 Casement Window

Whole-window U-value · W/(m²·K)

Glazing build-upU-value
5Low-e + 16A/Ar + 5 + 16A/Ar + 51.3 / 1.2
5Low-e + 16A/Ar + 5Low-e + 16A/Ar + 51.15 / 1.05
5Low-e + 16A/Ar (warm edge) + 5Low-e + 16A/Ar (warm edge) + 50.9 / 0.8

Paired U-values and A/Ar notation are retained as listed. The individual conditions are not defined; pairs are not ranges or assigned to a gas fill.

Wind resistance
Class 9
Watertightness
Class 6
Airtightness
Class 8
Airborne sound insulation
>42 dB

Catalogue-stated performance. Test standards, specimen sizes and acoustic rating methods are not specified; no international class conversion is implied. Confirm evidence for your final configuration.

System features

  • Multiple perimeter seals
  • Three listed glazing configurations
  • Warm-edge option for lower heat transfer

Applications

Low-energy housing and projects targeting reduced envelope heat loss.

View catalogue page 7 (PDF): 85 Casement Window
95 Casement Window illustrated catalogue configuration

Window system · Series 95

95 Casement Window

Enlarged profile sections support the design of larger glazed openings and facades with broad views.

Quote units: 95 Casement Window
Glazing & performance: 95 Casement Window

Whole-window U-value · W/(m²·K)

Glazing build-upU-value
5Low-e + 16A/Ar + 5Low-e + 16A/Ar + 51.1 / 1.0
5Low-e + 16A/Ar (warm edge) + 5Low-e + 16A/Ar (warm edge) + 50.85 / 0.75

Paired U-values and A/Ar notation are retained as listed. The individual conditions are not defined; pairs are not ranges or assigned to a gas fill.

Wind resistance
Class 9
Watertightness
Class 6
Airtightness
Class 8
Airborne sound insulation
>42 dB

Catalogue-stated performance. Test standards, specimen sizes and acoustic rating methods are not specified; no international class conversion is implied. Confirm evidence for your final configuration.

System features

  • Enlarged profile sections
  • Double Low-e glazing configurations
  • Warm-edge configuration listed

Applications

Large apartments, villas and panoramic residential facades with low-energy design targets.

View catalogue page 8 (PDF): 95 Casement Window
103 Tilt-and-Turn Window illustrated catalogue configuration

Window system · Series 103

103 Tilt-and-Turn Window

Inward-opening tilt-and-turn operation combines controlled ventilation with full opening for access and cleaning.

Quote units: 103 Tilt-and-Turn Window
Glazing & performance: 103 Tilt-and-Turn Window

Whole-window U-value · W/(m²·K)

Glazing build-upU-value
5Low-e + 18A/Ar (warm edge) + 5Low-e + 18A/Ar (warm edge) + 50.8 / 0.7

Paired U-values and A/Ar notation are retained as listed. The individual conditions are not defined; pairs are not ranges or assigned to a gas fill.

Wind resistance
Class 9
Watertightness
Class 6
Airtightness
Class 8
Airborne sound insulation
>42 dB

Catalogue-stated performance. Test standards, specimen sizes and acoustic rating methods are not specified; no international class conversion is implied. Confirm evidence for your final configuration.

System features

  • Inward-opening tilt-and-turn hardware
  • Multi-point locking
  • Continuous perimeter compression seals

Applications

Bedrooms, studies and living spaces in houses and large apartments.

View catalogue page 9 (PDF): 103 Tilt-and-Turn Window
103 Micro-Vent Window illustrated catalogue configuration

Window system · Series 103

103 Micro-Vent Window

A window format for larger residential openings, combining a broad glazed view with dedicated opening sections.

Quote units: 103 Micro-Vent Window
Glazing & performance: 103 Micro-Vent Window

Whole-window U-value · W/(m²·K)

Glazing build-upU-value
5Low-e + 18A/Ar (warm edge) + 5Low-e + 18A/Ar (warm edge) + 50.8 / 0.7

Paired U-values and A/Ar notation are retained as listed. The individual conditions are not defined; pairs are not ranges or assigned to a gas fill.

Wind resistance
Class 9
Watertightness
Class 6
Airtightness
Class 8
Airborne sound insulation
>42 dB

Catalogue-stated performance. Test standards, specimen sizes and acoustic rating methods are not specified; no international class conversion is implied. Confirm evidence for your final configuration.

System features

  • Large-opening design format
  • Multiple seals for thermal and acoustic comfort
  • Ventilation hardware to be confirmed by configuration

Applications

Large apartments, sky-garden housing and courtyard-facing residential openings.

View catalogue page 10 (PDF): 103 Micro-Vent Window
114 Curtain-Wall Window illustrated catalogue configuration

Window system · Series 114

114 Curtain-Wall Window

A curtain-wall-style window system with visible vertical framing and concealed horizontal framing for an integrated facade appearance.

Quote units: 114 Curtain-Wall Window
Glazing & performance: 114 Curtain-Wall Window

Whole-window U-value · W/(m²·K)

Glazing build-upU-value
5Low-e + 18A/Ar (warm edge) + 5Low-e + 18A/Ar (warm edge) + 50.9 / 0.8

Paired U-values and A/Ar notation are retained as listed. The individual conditions are not defined; pairs are not ranges or assigned to a gas fill.

Wind resistance
Class 9
Watertightness
Class 6
Airtightness
Class 8
Airborne sound insulation
>42 dB

Catalogue-stated performance. Test standards, specimen sizes and acoustic rating methods are not specified; no international class conversion is implied. Confirm evidence for your final configuration.

System features

  • Visible vertical / concealed horizontal framing
  • Wide glazed composition
  • Warm-edge glazing configuration listed

Applications

Detached villas, townhouses and private residences with coordinated facade glazing.

View catalogue page 11 (PDF): 114 Curtain-Wall Window
Insulated Entrance Door illustrated catalogue configuration

Door system · Insulated entrance

Insulated Entrance Door

An insulated entrance system with a polyurethane door core and multiple perimeter seals for residential entrances.

Quote units: Insulated Entrance Door
Glazing & performance: Insulated Entrance Door

Whole-door U-value · W/(m²·K)

AssemblyU-value
Insulated entrance-door assembly0.8

No glazing build-up is specified for this entrance-door assembly.

Wind resistance
Class 9
Watertightness
Class 6
Airtightness
Class 8
Airborne sound insulation
>42 dB

Catalogue-stated performance. Test standards, specimen sizes and acoustic rating methods are not specified; no international class conversion is implied. Confirm evidence for your final configuration.

System features

  • Polyurethane insulated door core
  • Multiple perimeter seals
  • Hardware and finish by project specification

Applications

Villas, large homes and main entrances to low-energy buildings.

View catalogue page 12 (PDF): Insulated Entrance Door
132 Lift-and-Slide Door illustrated catalogue configuration

Door system · Series 132

132 Lift-and-Slide Door

A lift-and-slide system for wide openings. The closing mechanism compresses the seals while sliding operation saves interior space.

Quote units: 132 Lift-and-Slide Door
Glazing & performance: 132 Lift-and-Slide Door

Whole-door U-value · W/(m²·K)

Glazing build-upU-value
5Low-e + 9A/Ar + 5Low-e + 9A/Ar + 51.4 / 1.3

Paired U-values and A/Ar notation are retained as listed. The individual conditions are not defined; pairs are not ranges or assigned to a gas fill.

Wind resistance
Class 9
Watertightness
Class 5
Airtightness
Class 7
Airborne sound insulation
>40 dB

Catalogue-stated performance. Test standards, specimen sizes and acoustic rating methods are not specified; no international class conversion is implied. Confirm evidence for your final configuration.

System features

  • Lift-and-slide operating mechanism
  • Compression sealing when closed
  • Wide-opening residential format

Applications

Courtyards, panoramic balconies and garden entrances.

View catalogue page 13 (PDF): 132 Lift-and-Slide Door
145 Side-Pressure Door illustrated catalogue configuration

Door system · Series 145

145 Side-Pressure Door

A side-pressure closing mechanism compresses the gaskets around large glazed openings, combining wide views with a sealed closure.

Quote units: 145 Side-Pressure Door
Glazing & performance: 145 Side-Pressure Door

Whole-door U-value · W/(m²·K)

Glazing build-upU-value
5Low-e + 9A/Ar + 5Low-e + 9A/Ar + 51.3 / 1.2

Paired U-values and A/Ar notation are retained as listed. The individual conditions are not defined; pairs are not ranges or assigned to a gas fill.

Wind resistance
Class 9
Watertightness
Class 5
Airtightness
Class 7
Airborne sound insulation
>40 dB

Catalogue-stated performance. Test standards, specimen sizes and acoustic rating methods are not specified; no international class conversion is implied. Confirm evidence for your final configuration.

System features

  • Side-pressure gasket compression
  • Large glazed opening format
  • Glazing and operating layout by project

Applications

Balcony renovations, sky-garden homes and large panoramic residential openings.

View catalogue page 14 (PDF): 145 Side-Pressure Door

Images illustrate catalogue configurations. Final opening layout, dimensions, finish and hardware are confirmed for each project. Series numbers are product identifiers.

Composite profiles, configured as a complete unit

Glass reinforcement and a thermoset polyurethane matrix form the pultruded frame profiles. Glazing, seals and hardware are selected with the complete assembly.
FIG. 2 Composite profile sectionSchematic · not to scale
Cutaway of a glass-fiber-reinforced polyurethane window frame, showing chambers and glazing interfaces
Illustrative section detail. Geometry and components vary by system.

Frame and glazing together

Match the chosen series to the opening size, insulating glass build-up, spacer and target whole-window U-value.

Opening, seals and hardware

Specify how each sash or door leaf operates, its handing, locks, handles and perimeter seals. Review the proposed size and glass weight together.

Finish and installation interface

Confirm interior and exterior colors on physical samples. Provide sill, jamb and head details, fixing requirements and drainage interfaces.

Fabricating locally? Explore window and door profiles →

Specify the performance of the complete assembly

The product tables reproduce the catalogue configurations. Select the glass, frame, size and operating hardware before confirming performance for your project.

Whole-window U-value

Uw describes the complete window; Ug describes the glass and Uf the frame. The window and door tables use W/(m²·K). Material conductivity is a different property.

Glazing build-up and warm edge

Low-e identifies a coated glass layer. A/Ar notation and warm-edge options are retained as listed. Confirm cavity fill, spacer, coating surfaces and safety-glass requirements.

Paired values need configuration confirmation

A pair such as 0.8 / 0.7 is reproduced as listed. Its individual conditions are not defined in the reference data; it is not assigned to air/argon fill or treated as a performance range.

Classes and acoustic values

Wind, water and air entries are catalogue classes with no stated test standard. Acoustic values retain the stated > symbol; no Rw, STC, OITC or international class conversion is implied.

Agree what your finished-unit quote includes

A quotation identifies the frame, glass, hardware, seals and accessories for each opening. Confirm installation materials, site labor, spare parts and delivery terms as part of the agreed scope.
Profile and finished-window quotation scope
Supply itemFinished units
FRP frame, sash and mullion sectionsIncluded in the agreed assembly
Glazing beads, gaskets and connectorsConfirm system and configuration
Glass and operating hardwareSpecify glass build-up and hardware
Cutting, machining and assemblyDefine factory assembly and glazing scope
Evidence and inspectionConfiguration-specific documents and agreed checks
Packing, freight and unloadingConfirm crate dimensions, delivery and unloading
Site installation and after-salesLocal installer and contract-defined service scope

From product selection to an opening schedule

Download the 16-page English catalog for the complete product range. Use one schedule row per opening configuration, with dimensions, quantity, operation, glazing, hardware and finish.

Opening ID
W01 / D01
Dimensions
Width × height + unit
Dimension basis
Rough opening or frame
Operation
Handing + viewing side
Configuration
Series, glass, hardware
Quantity
Units + delivery phase

Open the CSV in Excel or another spreadsheet app. Attach your schedule and drawings to the enquiry; up to 4 MB per submission. Missing details can be clarified during review.

  • CatalogPDF · 4.7 MB · 16 pages

    Finished Fiberglass Windows & Doors Catalog (Edition 2026.11)

    Issued by
    F1 Composite
    For
    Finished fiberglass windows and doors

    Eleven finished window and door families: casement, flush, tilt-and-turn, micro-vent, curtain-wall-style, insulated entrance, lift-and-slide and side-pressure systems. Includes glazing build-ups, catalogue-stated U-values, performance notes and an opening-schedule checklist. Confirm configuration-specific test evidence before ordering.

  • TemplateCSV · Editable template

    Finished Window & Door Schedule Template

    Issued by
    F1 Composite
    For
    FRP windows and doors

    For finished units: opening ID, series, dimensions, opening type, glazing, hardware, quantity and delivery requirements.

From specification to project delivery

Start with a sample evaluation, budget estimate, technical discussion or formal quotation. Agree the configuration and supporting documentation before releasing an order.
  1. Step 1

    Describe the project

    Identify project-specific requirements.

  2. Step 2

    Share your schedule

    Distinguish rough opening from finished frame size.

  3. Step 3

    Match the configuration

    Match evidence to the offered assembly.

  4. Step 4

    Review the quotation

    Agree included and excluded work.

  5. Step 5

    Approve drawings & samples

    Approve configuration before manufacture.

  6. Step 6

    Produce & inspect

    Factory checks follow the agreed scope.

  7. Step 7

    Pack & deliver

    Check packages and record any damage at receipt.

  8. Step 8

    Install & support

    Confirm installation and warranty responsibilities.

Plan delivery around your openings

FIG. 3 Window crateSchematic · not to scale
W01
Packing concept. The packing design is agreed for each order.

Plan around each opening and crate

Agree glass protection, crate size and weight, window-to-crate labels, unloading equipment and delivery phases. Check for damage at receipt and keep the window IDs with the installation schedule.

Port delivery, site delivery, unloading and installation are separate scopes. Confirm the local installation team and spare parts before ordering.

Finished window and door questions

Which finished window and door systems can I compare?

The finished-unit catalog covers 65, 72, 83 flush, 85, 95, 103 tilt-and-turn, 103 micro-vent and 114 curtain-wall-style windows, plus an insulated entrance door, 132 lift-and-slide door and 145 side-pressure door. Series numbers are product identifiers; confirm dimensions on the selected drawing.

Are these the same systems as the profile-supply catalog?

The finished-unit range has its own configurations and catalog. A matching number such as 65 does not establish interchangeability with a profile-supply series. Specify the purchasing route and full product name; confirm drawings, interfaces and scope for the proposed assembly.

What is included in a finished-unit quotation?

The quotation identifies the frame, glass, hardware, seals and agreed accessories, together with inspection, packing and delivery terms. Confirm installation materials, site labor and spare parts separately rather than assuming they are included.

Can one U-value be applied to every window size?

No. Whole-window performance changes with frame geometry, window size, glazing and edge details. Request data for the proposed assembly and distinguish whole-window Uw from glass Ug and frame Uf.

What should I send before requesting a price?

Start with the opening schedule, project location, required performance, glazing and hardware preferences. Drawings and quantities allow the unit configuration and documentation requirements to be reviewed before a formal quote.

What do paired U-values and performance classes mean?

The tables retain the catalogue U-value pairs, but the conditions for each value are not defined in the reference data. Wind, water and air classes have no stated test standard, and the sound figures have no stated Rw or STC method. Request configuration-specific documentation before using them as project acceptance criteria.

Bring us your window and door schedule

Share the selected series, opening schedule, glazing and hardware preferences, and project destination. We will clarify any undecided configuration details. We reply within one business day; a formal quotation follows once the specification and delivery are reviewed.

Window schedule
Window IDs, width × height and quantity, and whether sizes are rough opening or frame.
Operation and handing
The opening type of each window, left or right handing and the viewing side of the drawings.
Glass and hardware
Glass build-up, hardware, and the interior and exterior colors.
Project and delivery
Project city, performance targets, wall details, delivery phases and installation scope.
Get a quoteWhatsApp