Skip to content
F1-GRID· Grating

Fiberglass grating for industrial projects

Choose molded mesh or pultruded bearing-bar panels for walkways, platforms and access systems. Compare configurations, review the engineering inputs and send a panel schedule for quotation.

FIG. 1 Two constructionsPhotos · not to a common scale
Molded square meshMolded square mesh
Pultruded bearing barsPultruded bearing bars
Compare the integral molded mesh with directional pultruded bars.
Constructions
Molded & pultruded
Selection data
Dimensions & weights
Fixing systems
Matched 316SS clips
Procurement
Project & bulk enquiries
Get a project quoteHelp me selectWhatsApp

Whole panels or drawing-based requirements. Quantities, fabrication and delivery scope confirmed with your quote.

What does your walking surface need to do?

Wet & coastal access — application referenceCatalog photo

Wet & coastal access

Begin with drainage, top opening and the walking surface. Include exposure and cleaning requirements.

  • Surface and footwear
  • Clear opening
  • Support layout
Explore selection requirements
Platforms & maintenance walkways — application referenceCatalog photo

Platforms & maintenance walkways

Start with the support arrangement and bearing direction. Mark access openings and finished panel sizes.

  • Clear span and loads
  • Bearing-bar direction
  • Cutting and fixing scope
Prepare an engineering review

Application references; project specifications vary.

Two ways to build your walking surface

Fiberglass grating is also called fibreglass or GRP grating. The important choice is how the panel carries the load and fits the layout.

Molded vs pultruded grating

Molded vs pultruded grating
Selection questionMolded gratingPultruded grating
How is it made?Glass reinforcement and resin form an integral grid in a mold.Continuous pultruded bearing bars are joined with cross-rods.
Which direction spans?Square-mesh panels can support two-direction layouts; check the selected panel's load data.Bearing bars carry the main span. Cross-rods are not an equivalent load-bearing direction.
What geometry is specified?Mesh, clear opening, panel depth, panel size and support around cutouts.Bar shape, depth, spacing, cross-rod layout, panel size and bearing direction.
What controls the final choice?Loads, supports, deflection, openings, resin and surface.The same project checks, with the bearing bars aligned to the designed span.

Build your grating requirement

Select, compare and prepare your inquiry. Start with what you know, keep unknown details for review and attach drawings on the contact form.

Choose your starting point

See what to specify

Use these drawings to describe the support layout and the supply you need. Schematics only, not measured product or installation drawings.
FIG. 2 Specify the span, not just the panel lengthSchematic · not to scale
Bearing bars bridge the supports →Clear span: between support facesSupportSupport
For pultruded panels, mark bearing-bar direction on the layout. Cross-rods do not provide equivalent spanning capacity. Include support width, loads, cutouts and deflection requirements.
FIG. 3 Choose the supply scopeSchematic · not to scale
P01P02Whole panelsCut & markedFixing kitsConfirm dimensions, cutting, packing and freight scope
Request whole panels or finished pieces against a drawing. Add panel marks, openings and fixing requirements. Packing, kit contents and delivery arrangements are confirmed with the quotation.

Specify the opening, surface and service conditions

FIG. 4 Pitch is not the clear openingSchematic · not to scale
Pitch: center to centerClear opening
A mesh designation or bar-center dimension is not the unobstructed opening. Confirm the top clear opening and direction of travel where footwear, dropped objects or accessibility govern.

Match the resin to the environment

Identify chemical names, concentrations, exposure type and operating temperature. Discuss polyester or vinyl ester against that service; resin names alone do not establish compatibility.

Read about FRP resin systems

Choose the walking surface

For molded mesh, compare concave and gritted finishes. For pultruded bars, confirm the profile finish or bonded grit for the selected series. Match the surface to wet or dry use, footwear and cleaning, and specify the required slip-test method and acceptance criteria.

Check the full load case

State clear span, support width, uniform and concentrated loads, contact area and deflection limit. Cutouts, edge support and bearing-bar direction belong on the panel layout.

Request the applicable load data

Match the documents to your panel

Download the current selection data and clip drawings. For a load/deflection table or test report, identify the panel and service conditions so the documents match the proposed supply.

Project load & test data

Include series or mesh, clear span, support width, uniform/point load, load footprint and deflection limit. State resin, chemical exposure, temperature and any fire or slip-test requirement.

Request matching engineering data →

Plan the supply as well as the panel

For US, Canadian, Australian, New Zealand and UK enquiries, include the destination and required units. Panel specification, quantity, cutting, fixing kits, packing and freight determine the quoted scope.
  1. Step 1

    Quantity & samples

    Send panel quantities or total area, your preferred configuration and sample needs. Minimum production quantity and sample arrangements are confirmed with the quotation.

  2. Step 2

    Whole panels or a cut plan

    State the required finished sizes, openings, edge treatment, panel identification and fixing kits. We confirm the drawing and fabrication scope before order release.

  3. Step 3

    Packing & destination

    Give the delivery country, port or postcode and site handling constraints. The quotation defines packing, freight scope and the agreed Incoterm.

  4. Step 4

    Production & transit

    Share your required-on-site date. Production timing and transport time are confirmed separately after specification, quantity and destination review.

We will acknowledge your requirements within one business day and confirm the next step. A formal quotation follows specification and delivery review. Attach your layout to the enquiry, or describe the application and ask us to help shortlist a configuration.

Catalog dimensions identify standard section options, not live inventory. Confirm tooling, material, quantity and production timing in the quotation.

Fiberglass grating: selection & purchasing questions

Are fiberglass, fibreglass, FRP and GRP grating the same?

For the glass-reinforced panels in F1's range, these names describe the same material family. Fiberglass is the common US spelling; fibreglass and GRP are also used in the UK, Australia and New Zealand. Specify molded or pultruded construction, resin, geometry and project requirements rather than relying on the name alone.

How do I choose molded or pultruded grating?

Begin with the support layout and openings. Molded mesh suits many irregular cutouts and two-direction layouts; pultruded bearing bars provide a directional span. Compare the selected panel's load and deflection data before confirming thickness. Neither construction is automatically suitable for every load.

Which panel sizes and thicknesses are available?

The molded page lists mesh groups, depths, panel-size options, weights and open area. The pultruded page lists I-bar and T-bar series, depths and bar spacing. Download the current selection CSV or choose a row for quotation. Listed configurations are selection references, not a live-stock promise.

Can I request inch dimensions and US units?

Yes. State the required units and whether a dimension is nominal or exact. The page shows metric catalog values; inch equivalents are approximate conversions. A 25 mm panel is approximately 0.984 inches, not an exact one-inch stock specification.

What affects the price and minimum order?

Panel type, geometry, resin, surface, quantity, cutting, fixing kits, packing and destination affect the quotation. Send panel quantities or total area and the delivery port or postcode. Minimum quantity, sample arrangements, production timing and delivery scope are confirmed against that requirement.

Can I get load tables and a drawing review?

Send the series or mesh, clear span, support width, load type and footprint, deflection limit, resin and service conditions. Request the applicable grating load/deflection table and product documents. The CSV contains geometry and nominal weights; it is not an allowable-load table.

Send your grating requirements

Whole panels or drawing-based requirements. Send what you know; quantities, fabrication and delivery scope are confirmed with the quotation. We reply within one business day; a formal quotation follows once the specification and delivery are reviewed.

Panel type and size
Molded mesh or pultruded series, depth, and panel sizes or a cut plan with panel marks.
Span and loads
Clear span, support width, uniform and point loads, deflection limit and bearing-bar direction.
Service and surface
Chemicals and temperature, resin, walking surface, and any fire or slip-test requirement.
Fixing and delivery
Clip kits, quantity or total area, destination port or postcode and the required date.
Get a quoteWhatsApp