Skip to content
Datasheet

Fiberglass square tube 152×152×9.5 mm

Dimensions, section properties computed from the geometry, allowable loads by span and EN 13706 E23 mechanical data for the SHS 152×152×9.5 pultruded profile.

Model
SHS 152×152×9.5
EN 13706 grade
E23
Published mass
8.2 kg/m
Section area
5415 mm²
Request a quoteAsk the AI assistantWhatsApp

Start with your name and email. Product details and drawings can follow.

Cross-section and section properties

FIG. 1 SHS 152×152×9.5Drawn to scale

≈ 5.984 × 5.984 × 0.374 in, for reference only; the metric dimensions govern.

Dimensions of SHS 152×152×9.5
Side (D)152 mm
Wall thickness (t)9.5 mm
Mass per meter (published)8.2 kg/m
Section properties of SHS 152×152×9.5, calculated from the geometry
Section property (calculated)Value
Cross-section area A5415 mm²
Moment of inertia Ix1841 cm⁴
Moment of inertia Iy1841 cm⁴
Section modulus Sx242.2 cm³
Section modulus Sy242.2 cm³
Radius of gyration rx58.30 mm
Radius of gyration ry58.30 mm
Torsion constant J2749 cm⁴
Mass per meter (calculated)10.3 kg/m

Derived from the cross-section geometry by polygon integration. The published mass per meter is the catalog value; the calculated figure is a geometric cross-check. Because the modulus of FRP is about a tenth of steel's, deflection usually governs, so check spans in the profile calculator. For a planning budget per meter, enter these dimensions in the price estimator.

A dimensioned cross-section in DXF, free and without a login. It opens in AutoCAD, DraftSight, LibreCAD and other CAD packages.

What a 152×152×9.5 mm fiberglass square tube carries

Allowable service uniform load for SHS 152×152×9.5 as a simply supported beam, from the published FRP span tables. Design basis: EN 13706 Grade E23 (E-glass pultruded); LRFD, ASCE/SEI 74-23 (φ = 0.65, λ = 0.8 for occupancy live load, γ_Q = 1.6); Outdoor exposed (0.85 on strengths); deflection limit L/250 at service load (Timoshenko shear deflection included). Typical uses for this family: guardrail posts, solar purlins and light framing.
Allowable uniform load for SHS 152×152×9.5 by simply supported span
Span (m)Allowable UDL (kN/m)≈ lb/ftGoverning check
134.92392shear
1.523.31594shear
214.6999deflection
2.57.8531deflection
34.6314deflection
42.0135deflection
51.070.0deflection
60.5940.7deflection

Spans where the allowable load falls below 0.05 kN/m are omitted. Point loads, connections, lateral restraint and other exposures need their own check: open this section in the calculator or compare every size in the span tables.

Mechanical and physical properties

Laminate E23 · Isophthalic polyester (general purpose) / E-glass. Test methods are those of EN 13706 and the ISO and ASTM methods it cites.
Mechanical and physical properties of the SHS 152×152×9.5 laminate
PropertyValueTest method
Tensile modulus (longitudinal)23 GPaEN ISO 527-4
Tensile modulus (transverse)7 GPaEN ISO 527-4
Tensile strength (longitudinal)240 MPaEN ISO 527-4
Tensile strength (transverse)50 MPaEN ISO 527-4
Flexural strength (longitudinal)240 MPaEN ISO 14125
Flexural strength (transverse)100 MPaEN ISO 14125
Interlaminar shear strength (ILSS)30 MPaEN ISO 14130
Pin-bearing strength (longitudinal)150 MPaEN 13706-2 Annex E
Pin-bearing strength (transverse)70 MPaEN 13706-2 Annex E
Compressive strength (longitudinal)240 MPaEN ISO 604
Barcol hardness45ASTM D2583
Water absorption (24 h)0.6 %EN ISO 62
Resin:
Isophthalic unsaturated polyester
Glass content:
65–70% by weight
Density:
1.9 g/cm³
Grade:
E23
Fire:
Standard grade — not fire-retardant (specify an FR grade for ASTM E84 Class 1)

Data basis: F1-published general-purpose laminate (FRP Profile Design Manual DOC-PF-2026-EN Rev. B); ILSS 30 MPa published above the EN 13706 minimum of 25 MPa; transverse values are EN 13706-3 Table 1 grade minimums. Standard isophthalic polyester is not fire-retardant — for ASTM E84 Class 1 specify the FR-E23 grade. Compressive strength, Barcol hardness and water absorption are not specified by EN 13706 — the figures shown are typical industry values for this resin system, pending F1 certified test data; request certified values before final design.

Standards: EN 13706 Grade E23.

Values marked “Verify before release” are pending certified test data and are never estimated. Request batch-traceable certified data through the quote form before final design.

SHS 152×152×9.5: common questions

How much does a fiberglass square tube 152×152×9.5 mm weigh?

The published mass is 8.2 kg per meter (about 5.51 lb/ft), so a standard 6 m length weighs about 49.2 kg.

What load can a 152×152×9.5 mm fiberglass square tube carry?

On the published design basis (EN 13706 E23, LRFD to ASCE/SEI 74-23, outdoor exposure, L/250 deflection with shear deformation), the allowable service uniform load is about 34.9 kN/m over a simply supported 1 m span and 4.6 kN/m over 3 m (deflection governs at 3 m). Check point loads, connections and your own exposure in the calculator before release.

Is there a CAD drawing for SHS 152×152×9.5?

Yes. A dimensioned DXF cross-section is a free download on this page, with no login. It opens in AutoCAD, DraftSight, LibreCAD and other CAD packages.

What is the lead time for SHS 152×152×9.5?

SHS 152×152×9.5 is a catalog section in 6 m standard lengths. Catalog sections ship in 2–4 weeks. Catalog dimensions identify standard section options, not live inventory. Confirm tooling, material, quantity and production timing in the quotation.

Need a quote for SHS 152×152×9.5?

Send the dimensions, quantity, service conditions and destination. We reply within one business day.

Get a quoteWhatsApp