Wall section
Profile depth, effective cover width, laminate and interlock geometry define the wall section; its moment capacity is set by local buckling of the compression flange, so flange width-to-thickness matters as much as depth.
Profile depth, effective cover width, laminate and interlock geometry define the wall section; its moment capacity is set by local buckling of the compression flange, so flange width-to-thickness matters as much as depth.
Corner pieces, capping, walers, tie connections and sealing arrangements need a coordinated wall detail. Use oversized washers or plates at walers and tie rods to spread point loads into the sheet.
Vinyl ester resin for saltwater and aggressive soils, and a UV-stabilized surface veil on the face exposed above the waterline. Heavy ice flow or severe abrasion rules FRP sheets out.
A new section needs its own die: 4–8 weeks to make it and 6–10 weeks from an approved drawing to first delivery. The minimum order is 1,000 m per section. Samples are priced to the request, and the buyer pays the freight.
Published figures from full-section testing and design practice for pultruded FRP sheet piles. They show why buckling, not material strength, sizes the sheet.
| Item | Figure | What it means for the wall |
|---|---|---|
| Tested moment capacity of one section | 16,569 lb·ft/ft (73.7 kN·m/m) | Failure came at a flange compression stress of 15,201 psi (105 MPa), about 30% of the material's 50 ksi (345 MPa) compressive strength: local buckling governed. |
| Predicted capacity, same section | 14,472 lb·ft/ft (64.4 kN·m/m) by mechanics of materials; 13,128 lb·ft/ft (58.4 kN·m/m) by FEA | Both methods were conservative against the test, by 13% and 21%. |
| Allowable-stress safety factors | 2.0–2.5 bending · 2.0–3.0 shear · 2.5–3.0 connections | Applied to characteristic values derived per ASTM D7290 (80% lower confidence bound on the 5th percentile). |
| Recommended for design | 2.5 in bending, 3.0 in shear | Divide the characteristic moment by 2.5 to get the allowable wall moment. |
| Modulus for deflection | Lower of lengthwise tensile and compressive E | Deflection often governs the section choice. |
| Driving | SPT blow count of about 20 or less | Above that, pre-excavate or use a driving mandrel. |
Moments are per unit length of wall. Converted at 1 lb·ft/ft = 4.448 N·m/m. Source: ACMA Composites Technology Day 2021: FRP sheet piling design and installation (PDF).
CHECK 1
The wall is modelled in sheet-pile software such as SPW911 with soil layers, water levels, slopes, surcharge and scour. Its output moment, shear, wale force and deflection are then checked against the pile section.
CHECK 2
Design to characteristic values per ASTM D7290 with allowable-stress safety factors of about 2.5 in bending and 3.0 in shear. Take deflection with the lower of the lengthwise tensile and compressive modulus; deflection often decides the section.
CHECK 3
FRP sheets drive with a vibratory hammer in soils with SPT blow counts of about 20 or less. Stiffer ground needs pre-excavation, jetting or a steel driving mandrel; a trial pair of sheets on site shows which.
No. Seepage depends on the joint design, sealant, installation and hydraulic conditions. Specify a leakage criterion and verification method when a cutoff function is required.
The quotation covers the pile sections, caps and connectors made to your drawing. Wall design, driving and the installed performance stay with the project engineer and the piling contractor.
Start with a drawing and the intended use. These details help define the proposed supply package and qualification plan. We reply within one business day; a formal quotation follows once the specification and delivery are reviewed.