Section geometry
Flange width and thickness, overall depth, stem thickness and internal radii. Specify symmetry or any intentional offset.
Flange width and thickness, overall depth, stem thickness and internal radii. Specify symmetry or any intentional offset.
Fastener positions, contact width, adhesive bond area and cutouts, with the supported panel or equipment identified.
Resin and reinforcement chosen for exposure and loading; surface veil, color and bonding preparation agreed in the specification.
A new section needs its own die: 4–8 weeks to make it and 6–10 weeks from an approved drawing to first delivery. The minimum order is 1,000 m per section. Samples are priced to the request, and the buyer pays the freight.
Equal tees with a constant wall, calculated from the geometry at a laminate density of 1.9 g/cm³. Corner radii are ignored, so real sections differ by a few percent. Each size is made to order on a new die.
| Size B × H × t, mm | Area, mm² | Mass, kg/m | Centroid from flange top, mm | Ix, cm⁴ | Wx (stem tip), cm³ | Iy, cm⁴ |
|---|---|---|---|---|---|---|
| 25 × 25 × 3 | 141 | 0.27 | 7.4 | 0.8 | 0.46 | 0.4 |
| 38 × 38 × 5 | 355 | 0.67 | 11.3 | 4.7 | 1.77 | 2.3 |
| 50 × 50 × 5 | 475 | 0.90 | 14.3 | 11.3 | 3.16 | 5.3 |
| 50 × 50 × 6 | 564 | 1.07 | 14.7 | 13.1 | 3.72 | 6.3 |
| 75 × 75 × 6 | 864 | 1.64 | 21.0 | 46.9 | 8.68 | 21.2 |
| 75 × 75 × 8 | 1,136 | 2.16 | 21.7 | 60.2 | 11.29 | 28.4 |
| 100 × 100 × 8 | 1,536 | 2.92 | 28.0 | 148.2 | 20.57 | 67.1 |
| 100 × 100 × 10 | 1,900 | 3.61 | 28.7 | 180.0 | 25.24 | 84.1 |
| 150 × 150 × 10 | 2,900 | 5.51 | 41.2 | 637.2 | 58.57 | 282.4 |
Material for checks: EN 13706 E23 minimums, 23 GPa lengthwise modulus and 240 MPa lengthwise tensile strength. Ix is about the horizontal axis through the centroid; the stem tip is the extreme fiber, so Wx = Ix / (H − centroid).
CHECK 1
A tee is not symmetric about both axes. Identify the loaded flange, restraint and load eccentricity; bending, twisting and local flange behavior may need separate checks.
CHECK 2
Check bearing at the bolt holes, pull-through, bond preparation and how the flange transfers force into the stem. Holes across the flange cut the lengthwise fibers, so keep them out of the stem root.
CHECK 3
Approve the section drawing and inspection plan before tooling. Review trial lengths for dimensions, straightness and assembly fit before the production run.
Not at the same size. E23 fiberglass has a lengthwise modulus of 23 GPa against 210 GPa for steel, so a tee of the same dimensions deflects about nine times as much. Use the Ix column in the size table to pick a deeper section, then check the joint.
Yes. The die can give the flange and stem different thicknesses with a radiused corner between them. The thicker leg takes longest to cure, so it sets the line speed.
Start with a drawing and the intended use. These details help define the proposed supply package and qualification plan. We reply within one business day; a formal quotation follows once the specification and delivery are reviewed.