How to verify TÜV Rheinland report CN24KZ3A 002
Test report by TÜV Rheinland (Shanghai) Co., Ltd., issued 14 March 2025, naming Chongqing Fengdu New Material Co., Ltd. as client. Check it with the issuer before relying on it, and compare your copy with the file published here.
- Client
- Chongqing Fengdu New Material Co., Ltd.
- Issued
- 14 March 2025
- Issuer
- TÜV Rheinland
What the report says
| Report number | CN24KZ3A 002 |
|---|---|
| Order number | 326034308 |
| Issued by | TÜV Rheinland (Shanghai) Co., Ltd. |
| Client | Chongqing Fengdu New Material Co., Ltd. |
| Tested or certified item | Polymer composite PV module frames GFF-SS-3023, GFF-SD-3018, GFF-SD-3023, GFF-SD-3320 and GFF-SD-3323 with Jotun Jota Solar CL coating, to 2 PfG 2923/11.22 |
| Reported result | Pass, as stated on the report cover. Other clauses refer to CN24KZ3A 001. |
| Issued | 14 March 2025 |
Scope note. GFF-series PV frames with Jotun Jota Solar CL coating, tested to the coating-change clauses of 2 PfG 2923/11.22 with a Pass result stated on the cover; other clauses refer to CN24KZ3A 001. TÜV Rheinland does not permit reproduction in extracts without its approval, and the report does not authorize a test mark.
Who this report covers
The report names Chongqing Fengdu New Material Co., Ltd. as client. Chongqing Fengdu New Material Co., Ltd. is part of FengDu New Material. F1 Composite is FengDu's export company and supplies products made in FengDu's plants.
It covers the samples named in it. It does not cover products made by any other company, even when the same document is attached to another supplier's offer.
If another supplier sends you this report, ask for the holder's written permission to use it and check it with the issuer as described below. You can also send it to us, and we will tell you whether the product offered is ours.
What TÜV Rheinland says about using it: TÜV Rheinland states that the report relates only to the test sample, may not be reproduced in extracts without the test center's permission, must be used complete, and does not entitle anyone to carry a test mark.
Check it with TÜV Rheinland
- The report states that it is signed digitally only. The copy published here carries no embedded signature, so Acrobat Reader cannot check it; ask us for the signed file.
- TÜV Rheinland confirms the validity of the digital signature in a separate document when its client, the holder named above, asks for it. Tell us which project needs it and we will make the request.
- TÜV Rheinland's contacts as printed on the report: service@de.tuv.com, www.tuv.com.
Files published here 1 file
| File | Size | Digital signature | SHA-256 |
|---|---|---|---|
| Laboratory original | 1.4 MB | None | a8afcbdae59837ad010b1541c172486f5f8c192b7b5061b47aab06d28f9b7880 |
To compare a copy you hold, run certutil -hashfile file.pdf SHA256 on Windows or shasum -a 256 file.pdf on macOS and Linux.
A different value means your copy is not the file published here. That alone does not make it invalid, because an issuer may supply another signed copy, so check it with the issuer.
Received this document from another supplier?
Send it to us with the offer. We will confirm whether the product offered comes from FengDu's plants and whether the document applies to it. We reply within one business day.