Fiberglass wide flange beams: key facts
A fiberglass wide flange beam is a pultruded FRP I-section with flanges as wide as the section is deep. F1 Composite lists a 305 × 305 mm catalog WF and quotes other nominal WF sizes for columns, frames and beams that need weak-axis stiffness.
- Definition
- A wide flange (WF) beam is an I-shaped section whose flange width is about equal to its depth; a narrow-flange I-beam has flanges about half its depth.
- Weak-axis stiffness
- The catalog WF 305 × 305 mm has a calculated weak-axis Iy of 6,010 cm⁴, about 7 times that of the I 300×150×15 I-beam (851 cm⁴).
- Catalog size
- I 305×305×12.7 mm (about 12 × 12 × ½ in), 21.5 kg/m published catalog mass, 6 m standard length or cut to size.
- Imperial WF sizes
- Standard 4 × 4 × ¼ in to 12 × 12 × ½ in WF sizes are made to order, from about 3.5 to 21.5 kg/m calculated; a first custom run starts at 500 m.
- Typical uses
- Platform and stair columns, pipe-rack legs, equipment frames, cooling-tower structures and beams without continuous lateral bracing.
- Design basis
- Members are checked under the project's standard, for example ASCE/SEI 74-23 or CEN/TS 19101, including local flange buckling, global stability and deflection with shear.
WF beam vs I-beam: what the wider flange changes
| Property | WF 305×305×12.7 | I-beam 300×150×15 |
|---|---|---|
| Depth × flange width | 305 × 305 mm | 300 × 150 mm |
| Flange / web thickness | 12.7 mm | 15.0 mm |
| Catalog mass | 21.5 kg/m | 13.5 kg/m |
| Strong axis Ix | 18,870 cm⁴ | 11,610 cm⁴ |
| Weak axis Iy | 6,010 cm⁴ | 851 cm⁴ |
| Weak axis Wy | 394 cm³ | 114 cm³ |
| Radius of gyration rx / ry | 129 / 73 mm | 117 / 32 mm |
| Flange outstand b/2t | 12.0 | 5.0 |
In this pair the wide flange is heavier per metre and also stiffer about the strong axis, but its largest gain is about the weak axis: Iy, Wy and ry rise several times. Those properties govern column buckling, lateral-torsional buckling and bending about the minor axis. Where grating, decking or cross-members brace the compression flange and the load acts in one plane, the lighter narrow-flange I-beam is often sufficient.
The wider flange also has a larger outstand. Its b/2t ratio is higher, so local buckling of the compression flange needs its own check. See the fiberglass I-beam sizes for the narrow-flange range.
Fiberglass WF beam sizes
| Model | Drawing and quote | |||||||
|---|---|---|---|---|---|---|---|---|
| I 305×305×12.7 | 305≈ 12.008 in | 305≈ 12.008 in | 12.7 | 21.5 | 18,870 | 6,010 | 394.1 | DXFQuote |
Standard imperial WF sizes, 4 × 4 × ¼ in to 12 × 12 × ½ in
The equal-flange depth × width × thickness series commonly listed for fiberglass WF beams in North America. Section properties are calculated from the nominal section; mass is calculated at 1.9 g/cm³, the E23 reference laminate density, which gives the published 21.5 kg/m of the catalog 305 × 305 mm WF. Confirm finished mass, tolerances and tooling in the quotation.
| Designation (in) | H × B × t (mm) | Mass (kg/m) | Mass (lb/ft) | Area (cm²) | Ix (cm⁴) | Iy (cm⁴) | Wx (cm³) | rx / ry (mm) | b/2t | Supply route |
|---|---|---|---|---|---|---|---|---|---|---|
| WF 4 × 4 × ¼ | 101.6 × 101.6 × 6.35 | 3.5 | 2.37 | 18.6 | 330 | 111 | 65 | 42 / 24 | 8.0 | Made to order |
| WF 6 × 6 × ¼ | 152.4 × 152.4 × 6.35 | 5.4 | 3.60 | 28.2 | 1,177 | 375 | 155 | 65 / 36 | 12.0 | Made to order |
| WF 6 × 6 × ⅜ | 152.4 × 152.4 × 9.52 | 7.9 | 5.33 | 41.7 | 1,672 | 563 | 219 | 63 / 37 | 8.0 | Made to order |
| WF 8 × 8 × ⅜ | 203.2 × 203.2 × 9.52 | 10.7 | 7.18 | 56.3 | 4,129 | 1,333 | 406 | 86 / 49 | 10.7 | Made to order |
| WF 8 × 8 × ½ | 203.2 × 203.2 × 12.70 | 14.1 | 9.47 | 74.2 | 5,284 | 1,779 | 520 | 84 / 49 | 8.0 | Made to order |
| WF 10 × 10 × ½ | 254.0 × 254.0 × 12.70 | 17.8 | 11.94 | 93.6 | 10,660 | 3,472 | 840 | 107 / 61 | 10.0 | Made to order |
| WF 12 × 12 × ½ | 304.8 × 304.8 × 12.70 | 21.5 | 14.41 | 112.9 | 18,830 | 5,999 | 1,236 | 129 / 73 | 12.0 | Catalog 305×305×12.7 mm |
Planning lead times: 2–4 weeks for catalog sections, 4–6 weeks for an existing-die variant and 6–10 weeks with a new die. Custom runs start at 500 m, then 200 m for repeats.
Compare in the profile finderConvert inch and metric sizesA section not listed: custom pultrusion
When to specify a wide flange instead of an I-beam
Columns and posts
Flexural buckling is checked about the axis with the smaller radius of gyration. Equal flange width and depth raise the weak-axis radius, so a wide flange section is the usual open shape for platform columns, pipe-rack legs and equipment-frame posts.
Beams without continuous bracing
Lateral-torsional buckling resistance increases with the weak-axis second moment and the torsion constant. Where grating, decking or bracing does not restrain the compression flange, compare a WF section before adding bracing to a narrow-flange beam.
Frames with biaxial bending
Members that carry wind, equipment or handrail loads in two directions use the weak-axis section modulus as well as the strong-axis one. The calculated Wy of a WF section is several times that of an I-beam of similar depth.
Connections that need flange width
A wider flange leaves room for two bolt lines, clip angles and bearing plates. Edge distances, hole spacing and pin-bearing checks still follow the connection design for the selected laminate.
Typical projects are chemical plant platforms, cooling tower structures, cable-tray and pipe supports, and stair towers where the WF column carries pultruded grating and industrial handrail systems.
Design checks for a pultruded WF member
- Check 1
Deflection with shear
FRP has a low modulus relative to steel, and shear deformation of the web adds to bending deflection. Check both against the project limit with the moduli accepted for the laminate.
- Check 2
Local flange buckling
Wide flanges have larger outstands. The table lists b/2t for each size so the compression flange can be checked for local buckling under the selected design basis.
- Check 3
Global stability
Check column buckling about both axes and lateral-torsional buckling for the actual unbraced length. Use the effective lengths and restraint conditions of the real frame.
- Check 4
Sustained load and temperature
Creep, service temperature and moisture reduce long-term stiffness and strength. Apply the factors of the project's design standard instead of short-term catalog values.
FRP column buckling calculatorBeam deflection calculatorAllowable loads by spanFRP bolts for connections
Material reference · E23-ISO
Published reference values for the general-purpose isophthalic polyester laminate. Match the section, formulation and supporting documents before selecting design values for an order.
| Property | Reference value | Method reference |
|---|---|---|
| Tensile modulus (longitudinal)EN ISO 527-4 | 23 GPa | EN ISO 527-4 |
| Tensile modulus (transverse)EN ISO 527-4 | 7 GPa | EN ISO 527-4 |
| Tensile strength (longitudinal)EN ISO 527-4 | 240 MPa | EN ISO 527-4 |
| Flexural strength (longitudinal)EN ISO 14125 | 240 MPa | EN ISO 14125 |
| Interlaminar shear strength (ILSS)EN ISO 14130 | 30 MPa | EN ISO 14130 |
| Pin-bearing strength (longitudinal)EN 13706-2 Annex E | 150 MPa | EN 13706-2 Annex E |
| DensityEN ISO 1183 | 1.9 g/cm³ | EN ISO 1183 |
| Glass contentEN ISO 1172 | 65–70% by weight | EN ISO 1172 |
The listed moduli, tensile and flexural strengths, and pin-bearing strength use EN 13706-3 E23 minimums. ILSS, density and glass content are the published E23-ISO material references. These values and method names do not constitute a test report for the selected profile. Full property table and test methods
Reference laminate values for preliminary work. Use the properties accepted for the proposed WF laminate and the project's design basis.
Resin routes to review
- Isophthalic polyesterThe E23-ISO reference uses this resin family. Confirm its suitability for the profile and service conditions.
- Fire-retardant polyesterState the required fire test and classification, then confirm evidence for the offered formulation and specimen scope.
- Vinyl esterA candidate for chemical exposure. Provide the chemicals, concentrations, temperatures and exposure duration; specify fire requirements separately.
- PolyurethaneReview the proposed profile, processing route and mechanical requirements with the supplier.
- PhenolicA route to evaluate where fire, smoke or toxicity criteria apply. Confirm manufacturability and the relevant test evidence.
A change of resin, reinforcement, pigment or surface finish can change the applicable properties and evidence. Confirm the grade and reports for the offered configuration. Compare resin systems
Documents
- Data sheet1 sizes · web page
I-beam and wide flange datasheets
- Issued by
- F1 Composite
One page per size: dimensions, calculated section properties, E23 laminate data and, where published, allowable load by span.
- CADDXF · 1 sizes
I-beam and wide flange section drawings
- Issued by
- F1 Composite
Dimensioned cross-sections that open in AutoCAD, DraftSight or LibreCAD. Download one from its row in the size table; no login or email.
- Data sheetPDF · 3 MB
FRP Profile Design Manual — DOC-PF-2026-EN Rev. B
- Issued by
- F1 Composite
- For
- Structural shapes
Revision B (October 2026), generated from the website's catalog, laminate and design-basis data: EN 13706 E23 laminate values beside the grade minimums, section properties of all 114 catalog sizes, allowable uniform loads to the published LRFD screening basis, application guides, durability stated by resin formulation, fabrication and inspection. A preliminary-sizing reference, not a project approval or batch certificate; it supersedes the withdrawn Rev. A.
- CertificatePDF · 142 KB
EPD & Carbon Footprint — Pultruded GFRP Composite Profiles
- Issued by
- CABR
- For
- Standard profiles
Unofficial English summary of the environmental product declaration and carbon footprint analysis for pultruded GFRP composite profile products, with 1 m² functional unit. Calculation reference CABR-CFC-01(02)-2025(20030)1, cradle-to-gate 33,934.34 g CO₂e/m², distribution 254.59 g, cradle-to-grave 36,099.32 g. Standards: GB/T 24025-2009 (ISO 14025-aligned Type III EPD), GB/T 32161-2015, ISO 14067, PAS 2050. Issued by China Academy of Building Research Co., Ltd. (CABR) Certification Center on April 30, 2025. The original Chinese documents, with the holder and scope, are provided on request.
- CatalogOn request
Product Catalog 2024
- Issued by
- F1 Composite
- For
- All products
Complete catalog of standard pultruded FRP profiles with dimensions, properties, and ordering information.
- CertificateOn request
ISO 9001 Certificate
- For
- All products
Request the current quality-management certificate with its edition (ISO 9001:2015, or ISO 9001:2026 after transition), holder, validity and scope for your proposed supply.
- CertificateOn request
CE Declaration of Performance
- For
- All products
Request product-specific performance and applicable conformity documentation; confirm the intended use and assessment route.
Wide flange beam questions
What is a WF beam?
WF stands for wide flange. A WF beam is an I-shaped section whose flange width equals, or is close to, its depth, such as 12 × 12 × ½ in. The wide flanges give a much larger weak-axis stiffness than a narrow-flange I-beam of similar depth, which matters for columns and unbraced beams.
What is the difference between a WF beam and an I-beam?
In FRP catalogs an I-beam usually has a flange width of about half its depth (for example 300 × 150 mm), while a WF beam has a flange width about equal to its depth (305 × 305 mm). The narrow-flange I-beam is lighter for its depth and suits beams braced by grating or decking; the WF section adds weak-axis stiffness, buckling resistance and connection width.
Does an FRP WF designation mean the same as a steel W-shape such as W12×26?
No. A steel W-shape designation gives the nominal depth and the weight in pounds per foot. FRP wide flange sizes are written as depth × flange width × thickness, for example 12 × 12 × ½ in. Compare the actual dimensions and section properties, not the designation.
Can a fiberglass WF beam replace a steel wide flange of the same size?
Not size for size. Glass FRP has a much lower modulus than steel, so an FRP member selected for the same span and deflection limit is usually deeper or more closely supported. Select the FRP section from the project loads, deflection limit, restraints and design basis, then compare the complete assemblies.
Which fiberglass wide flange sizes does F1 Composite list?
The catalog lists I 305×305×12.7 (about 12 × 12 × ½ in) at 21.5 kg/m with a DXF drawing. The standard imperial sizes 4 × 4 × ¼, 6 × 6 × ¼, 6 × 6 × ⅜, 8 × 8 × ⅜, 8 × 8 × ½ and 10 × 10 × ½ in are made to order; plan 4–6 weeks for an existing-die variant or 6–10 weeks with a new die, confirmed in the quotation.
Which standards apply to a pultruded FRP wide flange beam?
ASCE/SEI 74-23 gives LRFD design rules for pultruded FRP structures in North America, and CEN/TS 19101 covers FRP structures in Europe. EN 13706 and ASTM D3917 deal with profile grades and dimensional tolerances. State which documents the project uses; a standard reference alone does not rate a member.
Quote fiberglass WF beams
Send the WF size or the steel section it replaces, member lengths, loads, unbraced lengths and service conditions, with quantities and the delivery destination. We reply within one business day; a formal quotation follows once the specification and delivery are reviewed.
- Section and quantity
- Catalog WF, nominal designation or required envelope, cut lengths and quantities.
- Member role
- Column, beam or frame member, effective lengths, bracing points and deflection limit.
- Connections
- Base plates, splices, hole patterns, bearing details and hardware material.
- Material and acceptance
- Exposure, temperature, fire requirement, design standard and required test records.