Skip to content
F1-STRUX· Wide flange beam

Fiberglass wide flange beams (FRP WF beams)

Pultruded fiberglass WF beams with flange width equal to depth. Compare the catalog wide flange with narrow-flange I-beams, check the standard 4 × 4 to 12 × 12 in sizes with mass and section properties, and define the columns, frames or unbraced beams you need quoted.

FIG. 1 I 305×305×12.7Schematic · not to scale
A
11,298 mm²
Ix
18,871.2 cm⁴
Mass
21.5 kg/m
Cross-section of I 305×305×12.7, one catalog size. Mass is the published catalog value; A and Ix are calculated from the nominal section.
Catalog WF
305×305×12.7 mm
Nominal range
4 × 4 to 12 × 12 in
Flange ratio
B ≈ H
Length
6 m or cut

Last updated · Reviewed by Yifan Liu, Application Engineer

Fiberglass wide flange beams: key facts

A fiberglass wide flange beam is a pultruded FRP I-section with flanges as wide as the section is deep. F1 Composite lists a 305 × 305 mm catalog WF and quotes other nominal WF sizes for columns, frames and beams that need weak-axis stiffness.

Definition
A wide flange (WF) beam is an I-shaped section whose flange width is about equal to its depth; a narrow-flange I-beam has flanges about half its depth.
Weak-axis stiffness
The catalog WF 305 × 305 mm has a calculated weak-axis Iy of 6,010 cm⁴, about 7 times that of the I 300×150×15 I-beam (851 cm⁴).
Catalog size
I 305×305×12.7 mm (about 12 × 12 × ½ in), 21.5 kg/m published catalog mass, 6 m standard length or cut to size.
Imperial WF sizes
Standard 4 × 4 × ¼ in to 12 × 12 × ½ in WF sizes are made to order, from about 3.5 to 21.5 kg/m calculated; a first custom run starts at 500 m.
Typical uses
Platform and stair columns, pipe-rack legs, equipment frames, cooling-tower structures and beams without continuous lateral bracing.
Design basis
Members are checked under the project's standard, for example ASCE/SEI 74-23 or CEN/TS 19101, including local flange buckling, global stability and deflection with shear.

WF beam vs I-beam: what the wider flange changes

Both rows come from the published catalog. Section properties are calculated from the nominal, sharp-cornered geometry for preliminary comparison.
Catalog wide flange beam compared with a narrow-flange FRP I-beam of similar depth
PropertyWF 305×305×12.7I-beam 300×150×15
Depth × flange width305 × 305 mm300 × 150 mm
Flange / web thickness12.7 mm15.0 mm
Catalog mass21.5 kg/m13.5 kg/m
Strong axis Ix18,870 cm⁴11,610 cm⁴
Weak axis Iy6,010 cm⁴851 cm⁴
Weak axis Wy394 cm³114 cm³
Radius of gyration rx / ry129 / 73 mm117 / 32 mm
Flange outstand b/2t12.05.0

In this pair the wide flange is heavier per metre and also stiffer about the strong axis, but its largest gain is about the weak axis: Iy, Wy and ry rise several times. Those properties govern column buckling, lateral-torsional buckling and bending about the minor axis. Where grating, decking or cross-members brace the compression flange and the load acts in one plane, the lighter narrow-flange I-beam is often sufficient.

The wider flange also has a larger outstand. Its b/2t ratio is higher, so local buckling of the compression flange needs its own check. See the fiberglass I-beam sizes for the narrow-flange range.

Fiberglass WF beam sizes

Catalog rows carry the published mass, a datasheet and a DXF drawing. Dimensions in mm; Ix, Iy, Wx and Wy are calculated from the nominal section.
FRP wide flange catalog sizes, published mass and nominal section properties. Select a column heading to sort.
ModelDrawing and quote
I 305×305×12.7305≈ 12.008 in305≈ 12.008 in12.721.518,8706,010394.1DXFQuote

Standard imperial WF sizes, 4 × 4 × ¼ in to 12 × 12 × ½ in

The equal-flange depth × width × thickness series commonly listed for fiberglass WF beams in North America. Section properties are calculated from the nominal section; mass is calculated at 1.9 g/cm³, the E23 reference laminate density, which gives the published 21.5 kg/m of the catalog 305 × 305 mm WF. Confirm finished mass, tolerances and tooling in the quotation.

Standard imperial fiberglass wide flange beam designations with calculated section properties
Designation (in)H × B × t (mm)Mass (kg/m)Mass (lb/ft)Area (cm²)Ix (cm⁴)Iy (cm⁴)Wx (cm³)rx / ry (mm)b/2tSupply route
WF 4 × 4 × ¼101.6 × 101.6 × 6.353.52.3718.63301116542 / 248.0Made to order
WF 6 × 6 × ¼152.4 × 152.4 × 6.355.43.6028.21,17737515565 / 3612.0Made to order
WF 6 × 6 × ⅜152.4 × 152.4 × 9.527.95.3341.71,67256321963 / 378.0Made to order
WF 8 × 8 × ⅜203.2 × 203.2 × 9.5210.77.1856.34,1291,33340686 / 4910.7Made to order
WF 8 × 8 × ½203.2 × 203.2 × 12.7014.19.4774.25,2841,77952084 / 498.0Made to order
WF 10 × 10 × ½254.0 × 254.0 × 12.7017.811.9493.610,6603,472840107 / 6110.0Made to order
WF 12 × 12 × ½304.8 × 304.8 × 12.7021.514.41112.918,8305,9991,236129 / 7312.0Catalog 305×305×12.7 mm

Planning lead times: 2–4 weeks for catalog sections, 4–6 weeks for an existing-die variant and 6–10 weeks with a new die. Custom runs start at 500 m, then 200 m for repeats.

Compare in the profile finderConvert inch and metric sizesA section not listed: custom pultrusion

When to specify a wide flange instead of an I-beam

  • Columns and posts

    Flexural buckling is checked about the axis with the smaller radius of gyration. Equal flange width and depth raise the weak-axis radius, so a wide flange section is the usual open shape for platform columns, pipe-rack legs and equipment-frame posts.

  • Beams without continuous bracing

    Lateral-torsional buckling resistance increases with the weak-axis second moment and the torsion constant. Where grating, decking or bracing does not restrain the compression flange, compare a WF section before adding bracing to a narrow-flange beam.

  • Frames with biaxial bending

    Members that carry wind, equipment or handrail loads in two directions use the weak-axis section modulus as well as the strong-axis one. The calculated Wy of a WF section is several times that of an I-beam of similar depth.

  • Connections that need flange width

    A wider flange leaves room for two bolt lines, clip angles and bearing plates. Edge distances, hole spacing and pin-bearing checks still follow the connection design for the selected laminate.

Typical projects are chemical plant platforms, cooling tower structures, cable-tray and pipe supports, and stair towers where the WF column carries pultruded grating and industrial handrail systems.

Design checks for a pultruded WF member

  1. Check 1

    Deflection with shear

    FRP has a low modulus relative to steel, and shear deformation of the web adds to bending deflection. Check both against the project limit with the moduli accepted for the laminate.

  2. Check 2

    Local flange buckling

    Wide flanges have larger outstands. The table lists b/2t for each size so the compression flange can be checked for local buckling under the selected design basis.

  3. Check 3

    Global stability

    Check column buckling about both axes and lateral-torsional buckling for the actual unbraced length. Use the effective lengths and restraint conditions of the real frame.

  4. Check 4

    Sustained load and temperature

    Creep, service temperature and moisture reduce long-term stiffness and strength. Apply the factors of the project's design standard instead of short-term catalog values.

FRP column buckling calculatorBeam deflection calculatorAllowable loads by spanFRP bolts for connections

Material reference · E23-ISO

Published reference values for the general-purpose isophthalic polyester laminate. Match the section, formulation and supporting documents before selecting design values for an order.

PropertyReference valueMethod reference
Tensile modulus (longitudinal)EN ISO 527-423 GPaEN ISO 527-4
Tensile modulus (transverse)EN ISO 527-47 GPaEN ISO 527-4
Tensile strength (longitudinal)EN ISO 527-4240 MPaEN ISO 527-4
Flexural strength (longitudinal)EN ISO 14125240 MPaEN ISO 14125
Interlaminar shear strength (ILSS)EN ISO 1413030 MPaEN ISO 14130
Pin-bearing strength (longitudinal)EN 13706-2 Annex E150 MPaEN 13706-2 Annex E
DensityEN ISO 11831.9 g/cm³EN ISO 1183
Glass contentEN ISO 117265–70% by weightEN ISO 1172

The listed moduli, tensile and flexural strengths, and pin-bearing strength use EN 13706-3 E23 minimums. ILSS, density and glass content are the published E23-ISO material references. These values and method names do not constitute a test report for the selected profile. Full property table and test methods

Reference laminate values for preliminary work. Use the properties accepted for the proposed WF laminate and the project's design basis.

Resin routes to review

  • Isophthalic polyesterThe E23-ISO reference uses this resin family. Confirm its suitability for the profile and service conditions.
  • Fire-retardant polyesterState the required fire test and classification, then confirm evidence for the offered formulation and specimen scope.
  • Vinyl esterA candidate for chemical exposure. Provide the chemicals, concentrations, temperatures and exposure duration; specify fire requirements separately.
  • PolyurethaneReview the proposed profile, processing route and mechanical requirements with the supplier.
  • PhenolicA route to evaluate where fire, smoke or toxicity criteria apply. Confirm manufacturability and the relevant test evidence.

A change of resin, reinforcement, pigment or surface finish can change the applicable properties and evidence. Confirm the grade and reports for the offered configuration. Compare resin systems

Review available documents and their scope

Documents

  • Data sheet1 sizes · web page

    I-beam and wide flange datasheets

    Issued by
    F1 Composite

    One page per size: dimensions, calculated section properties, E23 laminate data and, where published, allowable load by span.

  • CADDXF · 1 sizes

    I-beam and wide flange section drawings

    Issued by
    F1 Composite

    Dimensioned cross-sections that open in AutoCAD, DraftSight or LibreCAD. Download one from its row in the size table; no login or email.

  • Data sheetPDF · 3 MB

    FRP Profile Design Manual — DOC-PF-2026-EN Rev. B

    Issued by
    F1 Composite
    For
    Structural shapes

    Revision B (October 2026), generated from the website's catalog, laminate and design-basis data: EN 13706 E23 laminate values beside the grade minimums, section properties of all 114 catalog sizes, allowable uniform loads to the published LRFD screening basis, application guides, durability stated by resin formulation, fabrication and inspection. A preliminary-sizing reference, not a project approval or batch certificate; it supersedes the withdrawn Rev. A.

  • CertificatePDF · 142 KB

    EPD & Carbon Footprint — Pultruded GFRP Composite Profiles

    Issued by
    CABR
    For
    Standard profiles

    Unofficial English summary of the environmental product declaration and carbon footprint analysis for pultruded GFRP composite profile products, with 1 m² functional unit. Calculation reference CABR-CFC-01(02)-2025(20030)1, cradle-to-gate 33,934.34 g CO₂e/m², distribution 254.59 g, cradle-to-grave 36,099.32 g. Standards: GB/T 24025-2009 (ISO 14025-aligned Type III EPD), GB/T 32161-2015, ISO 14067, PAS 2050. Issued by China Academy of Building Research Co., Ltd. (CABR) Certification Center on April 30, 2025. The original Chinese documents, with the holder and scope, are provided on request.

  • CatalogOn request

    Product Catalog 2024

    Issued by
    F1 Composite
    For
    All products

    Complete catalog of standard pultruded FRP profiles with dimensions, properties, and ordering information.

  • CertificateOn request

    ISO 9001 Certificate

    For
    All products

    Request the current quality-management certificate with its edition (ISO 9001:2015, or ISO 9001:2026 after transition), holder, validity and scope for your proposed supply.

  • CertificateOn request

    CE Declaration of Performance

    For
    All products

    Request product-specific performance and applicable conformity documentation; confirm the intended use and assessment route.

All downloads and CADTest reports and their scope

Wide flange beam questions

What is a WF beam?

WF stands for wide flange. A WF beam is an I-shaped section whose flange width equals, or is close to, its depth, such as 12 × 12 × ½ in. The wide flanges give a much larger weak-axis stiffness than a narrow-flange I-beam of similar depth, which matters for columns and unbraced beams.

What is the difference between a WF beam and an I-beam?

In FRP catalogs an I-beam usually has a flange width of about half its depth (for example 300 × 150 mm), while a WF beam has a flange width about equal to its depth (305 × 305 mm). The narrow-flange I-beam is lighter for its depth and suits beams braced by grating or decking; the WF section adds weak-axis stiffness, buckling resistance and connection width.

Does an FRP WF designation mean the same as a steel W-shape such as W12×26?

No. A steel W-shape designation gives the nominal depth and the weight in pounds per foot. FRP wide flange sizes are written as depth × flange width × thickness, for example 12 × 12 × ½ in. Compare the actual dimensions and section properties, not the designation.

Can a fiberglass WF beam replace a steel wide flange of the same size?

Not size for size. Glass FRP has a much lower modulus than steel, so an FRP member selected for the same span and deflection limit is usually deeper or more closely supported. Select the FRP section from the project loads, deflection limit, restraints and design basis, then compare the complete assemblies.

Which fiberglass wide flange sizes does F1 Composite list?

The catalog lists I 305×305×12.7 (about 12 × 12 × ½ in) at 21.5 kg/m with a DXF drawing. The standard imperial sizes 4 × 4 × ¼, 6 × 6 × ¼, 6 × 6 × ⅜, 8 × 8 × ⅜, 8 × 8 × ½ and 10 × 10 × ½ in are made to order; plan 4–6 weeks for an existing-die variant or 6–10 weeks with a new die, confirmed in the quotation.

Which standards apply to a pultruded FRP wide flange beam?

ASCE/SEI 74-23 gives LRFD design rules for pultruded FRP structures in North America, and CEN/TS 19101 covers FRP structures in Europe. EN 13706 and ASTM D3917 deal with profile grades and dimensional tolerances. State which documents the project uses; a standard reference alone does not rate a member.

Quote fiberglass WF beams

Send the WF size or the steel section it replaces, member lengths, loads, unbraced lengths and service conditions, with quantities and the delivery destination. We reply within one business day; a formal quotation follows once the specification and delivery are reviewed.

Section and quantity
Catalog WF, nominal designation or required envelope, cut lengths and quantities.
Member role
Column, beam or frame member, effective lengths, bracing points and deflection limit.
Connections
Base plates, splices, hole patterns, bearing details and hardware material.
Material and acceptance
Exposure, temperature, fire requirement, design standard and required test records.
Get a quoteWhatsApp