Skip to content
Engineering evidence

Find the document that matches your product

F1 Composite publishes 13 documents: SGS full-section modulus tests of 40.8 and 41.5 GPa, a Passive House Institute window certificate at Uw 0.78 W/(m²·K), Intertek AS 2047 window and door reports, TÜV Rheinland and CPVT PV frame reports and an SGS UL 94 V-0 material test. Each result applies only to the item named in the document.

Last updated

Review a catalog configuration

Keep the section, material dataset and catalog revision together when comparing documents or requesting a quote.

Choose a profile to review its current nominal dimensions, reference drawing, material and evidence scope. A family name or resin grade alone does not identify a tested configuration.

View the full evidence library

Reported results at a glance 9 reports

One row per test report or certificate, as printed in the original. A result covers the tested specimen or stated configuration only. It is not a design allowable or a certification of other products.
Results reported in F1 Composite's published test reports and certificates
DocumentTested itemMethodReported resultDate
SGS SHIN2608002943CM01_ENSquare tube sample; the report lists specification 60605 and specimen 2160 × 90 × 90 mmEN 13706-2 Annex D, 1,800 mm spanFull-section modulus 40.8 GPa, mean of three specimens (41.2, 41.1, 40.1)Issued
SGS SHIN2608002943CM02_ENSquare tube sample; the report lists specification 90905 and specimen 1440 × 60 × 60 mmEN 13706-2 Annex D, 1,200 mm spanFull-section modulus 41.5 GPa, mean of three specimens (41.1, 42.1, 41.3)Issued
Passive House Institute 2491wi03Fengdu Passive GFRP 90 Series window framePHI component certificate, cool-temperate climateUw 0.78 W/(m²·K) with Ug 0.70 W/(m²·K); efficiency class phBValid until
Intertek 240821010SHF-00180 Series turn-and-tilt window, 1200 × 1800 mmAS/NZS 4420.1-2016 test sequence against AS 2047-2014 (Amdt 2-2017)Results met the applicable AS 2047-2014 requirements, as concluded in the reportIssued
Intertek 240821010SHF-002Historical 140 Series lift-sliding door, 3000 × 2400 mmAS/NZS 4420.1-2016 test sequence against AS 2047-2014 (Amdt 2-2017)Results met the applicable AS 2047-2014 requirements, as concluded in the reportIssued
Wuxi / CPVT 2025DACS20319Composite PV module frame, all-weather modified resinMethods listed for each property in the reportMean tensile strength 1,310 MPa; flexural strength 1,060 MPa; flexural modulus 48.0 GPa; HDT above 290 °C; flammability V-1. No pass/fail assessment.Issued
TÜV Rheinland CN24KZ3A 002GFF-series polymer composite PV frames with Jotun Jota Solar CL coating2 PfG 2923/11.22, coating-change clausesPass, as stated on the report cover. Other clauses refer to CN24KZ3A 001.Issued
TÜV Rheinland CN24KZ3A 003GFF-series polymer composite PV frames with B9986S polyester coating2 PfG 2923/11.22, coating-change clausesPass, as stated on the report cover. Other clauses refer to CN24KZ3A 001.Issued
SGS GZMR260702529004Composite profile material E-TS-AB, 10.1 mm longitudinal specimensUL 94-2023 Rev.2-2024, Section 8 (vertical burning)V-0 at 10.1 mm. Report marked for internal reference.Issued

Intertek and TÜV Rheinland rows give the conclusion printed in each report, because both laboratories restrict partial reproduction. Open the complete report for the measured values. Data sheets and the window catalog are listed below but not tabulated.

All documents 13 documents

Confirm the certificate holder, product or specimen, report number, method, date and scope. EN 13706 and ASTM D3917 are specification references, not proof of blanket certification. CE/UKCA documentation depends on the product, intended use and applicable assessment route. The original document controls its holder, issue date, validity and scope. Each test report and certificate has a verification page naming its holder, the issuer's own check and the SHA-256 of the published file. For material or batch-specific records, request the applicable evidence.

13 documents

Test report · SHIN2608002943CM01_EN

E40 evidence — SGS full-section test, 40.8 GPa

SGS SHIN2608002943CM01_EN, issued 2026-09-07: full-section test to EN 13706-2 Annex D, 40.8 GPa average from three specimens. Page 1 specification 60605; page 3 specimen 2160 × 90 × 90 mm. These size identifiers need clarification before size-specific qualification. Results apply only to the tested samples; conclusion N/A, with an internal-reference use note. Supports the reported 40 GPa-class result, not EN 13706 E40 certification or a design allowable.

Evidence scope
Tested specimen only
Holder / publisher
Chongqing Xianju New Material Co., Ltd.
Issued

Confirm applicability

The report's specification and specimen dimensions need reconciliation. Neither size similarity nor an E40 label binds the report to a catalog section or resin.

Test report · SHIN2608002943CM02_EN

E40 evidence — SGS full-section test, 41.5 GPa

SGS SHIN2608002943CM02_EN, issued 2026-09-07: full-section test to EN 13706-2 Annex D, 41.5 GPa average from three specimens. Page 1 specification 90905; page 3 specimen 1440 × 60 × 60 mm. These size identifiers need clarification before size-specific qualification. Results apply only to the tested samples; conclusion N/A, with an internal-reference use note. Supports the reported 40 GPa-class result, not EN 13706 E40 certification or a design allowable.

Evidence scope
Tested specimen only
Holder / publisher
Chongqing Xianju New Material Co., Ltd.
Issued

Confirm applicability

The report's specification and specimen dimensions need reconciliation. Neither size similarity nor an E40 label binds the report to a catalog section or resin.

Component certificate · PHI 2491wi03

90-series GFRP window component certificate

PHI 2491wi03 names Chongqing Xianju New Material Co., Ltd. and Fengdu Passive GFRP 90 Series. The stated configuration is cool-temperate, efficiency class phB, Uw 0.78 W/(m²·K) with Ug 0.70; valid until 31 December 2026. It is not Arctic-climate, PHIUS or blanket F1-window certification. Confirm the original and proposed configuration.

Evidence scope
Certificate configuration only
Holder / publisher
Chongqing Xianju New Material Co., Ltd.
Valid until

Does not establish this configuration

This document concerns a window or door configuration, not the selected structural profile.

Test report · Intertek 240821010SHF-001

Turn-and-tilt GFRP window test report

AS 2047 testing of the identified window specimen. Match dimensions, glazing, hardware, pressure and test conditions before using the results.

Evidence scope
Tested specimen only
Holder / publisher
Fengdu New Material (Yancheng) Co., Ltd.
Issued

Does not establish this configuration

This document concerns a window or door configuration, not the selected structural profile.

Test report · Intertek 240821010SHF-002

Lift-sliding GFRP door test report

Historical 140 Series Lift-Sliding Door specimen, 3000 × 2400 mm, as named in Intertek 240821010SHF-002. The original report is preserved. It does not automatically cover the current 140 Series Compression-Seal Sliding Door; configuration equivalence requires technical verification.

Evidence scope
Tested specimen only
Holder / publisher
Fengdu New Material (Yancheng) Co., Ltd.
Issued

Does not establish this configuration

This document concerns a window or door configuration, not the selected structural profile.

Technical reference · DOC-PF-2026-EN Rev. B

FRP profile design manual

Revision B (October 2026), generated from the website's catalog, laminate and design-basis data: EN 13706 E23 laminate values beside the grade minimums, section properties of all 114 catalog sizes, allowable uniform loads to the published LRFD screening basis, application guides, durability stated by resin formulation, fabrication and inspection. A preliminary-sizing reference, not a project approval or batch certificate; it supersedes the withdrawn Rev. A.

Evidence scope
Technical reference
Holder / publisher
Published by F1 Composite; see the document for its data sources

Reference only

Use the stated design basis and material assumptions. The manual is not a specimen test, batch certificate or project approval.

Technical reference · PU-GF data sheet

PU-GF pultruded profile mechanical data

The material system and methods identified in the sheet. Confirm whether each value is typical, measured or a design value before applying it to another laminate or section.

Evidence scope
Technical reference
Holder / publisher
Published by F1 Composite; see the document for its data sources

Reference only

Material reference only. Confirm reinforcement, resin, value provenance and applicability to the selected section.

Technical reference · GFRP and CFRP laminate data sheet

Wind-energy pultruded laminate data

The tested laminate and reinforcement described in the document. Fatigue and fiber-content results apply to the stated specimens, not all blade or spar-cap designs.

Evidence scope
Technical reference
Holder / publisher
Published by F1 Composite; see the document for its data sources

Does not establish this configuration

This laminate data sheet concerns wind-energy panels, not the selected structural section.

Technical reference · Window and door catalog

Pultruded FRP window and door catalog

Nine-series purchasing reference: 50, 55, 60, 65, 70, 80, 90 casement, 90 sliding and 140 compression-seal sliding. Covers separate profile and finished-unit procurement paths, updated profile codes and configuration-specific evidence boundaries. Confirm drawings, glazing, hardware and supply scope at quotation.

Evidence scope
Technical reference
Holder / publisher
Published by F1 Composite; see the document for its data sources

Does not establish this configuration

This document concerns a window or door configuration, not the selected structural profile.

Test report · Wuxi / CPVT 2025DACS20319

PV module frame material test report

Composite PV module frame in all-weather modified resin: mean tensile strength 1,310 MPa, flexural strength 1,060 MPa, flexural modulus 48.0 GPa, HDT above 290 °C and flammability V-1, with UV, damp-heat, humidity-freeze, thermal-cycle, salt-mist and ammonia exposure results. The report gives measurements without a pass/fail conclusion, and its salt-mist cycle count and duration are inconsistent.

Evidence scope
Tested specimen only
Holder / publisher
Chongqing Xianju New Material Co., Ltd.
Issued

Does not establish this configuration

This report concerns the identified PV frame and material/coating, not the selected structural profile.

Test report · TÜV Rheinland CN24KZ3A 002

PV frame coating test report: Jotun Jota Solar CL

GFF-series PV frames with Jotun Jota Solar CL coating, tested to the coating-change clauses of 2 PfG 2923/11.22 with a Pass result stated on the cover; other clauses refer to CN24KZ3A 001. TÜV Rheinland does not permit reproduction in extracts without its approval, and the report does not authorize a test mark.

Evidence scope
Tested specimen only
Holder / publisher
Chongqing Fengdu New Material Co., Ltd.
Issued

Does not establish this configuration

This report concerns the identified PV frame and material/coating, not the selected structural profile.

Test report · TÜV Rheinland CN24KZ3A 003

PV frame coating test report: B9986S polyester

GFF-series PV frames with B9986S polyester coating, tested to the coating-change clauses of 2 PfG 2923/11.22 with a Pass result stated on the cover; other clauses refer to CN24KZ3A 001. TÜV Rheinland does not permit reproduction in extracts without its approval, and the report does not authorize a test mark.

Evidence scope
Tested specimen only
Holder / publisher
Chongqing Fengdu New Material Co., Ltd.
Issued

Does not establish this configuration

This report concerns the identified PV frame and material/coating, not the selected structural profile.

Test report · SGS GZMR260702529004

Composite profile material flammability test report

Composite profile material E-TS-AB: V-0 to UL 94-2023 Rev.2-2024 Section 8 at 10.1 mm thickness. The result does not establish V-0 for thin-wall PV frames, and SGS marks the report for internal reference.

Evidence scope
Tested specimen only
Holder / publisher
Chongqing Xianju New Material Co., Ltd.
Issued

Does not establish this configuration

The UL 94 result is for E-TS-AB longitudinal sheet specimens at 10.1 mm. It cannot establish V-0 for a different material, tube or thickness.

Keep the result with its scope

When specifying, comparing or quoting a result, keep the tested item and its conditions beside the number.
  1. Identify the document title, issuer, report number and original issue date. Follow its verification page to the full original; the catalog revision is a separate identifier.
  2. Name the tested specimen or certificate configuration, method and conditions. Check material, section, thickness, direction, span, coating or complete assembly as applicable.
  3. Distinguish a reported test result, reference material value, calculated screening result and approved design value. A shared grade or similar dimension does not establish equivalence.
  4. Keep unknowns visible. An unverified specimen mapping, missing first-article result or expired certificate needs review before project use.

For a new machined part, record the approved drawing revision, functional datums, agreed limits, measurement setup, actual observations and disposition in the blank first-article record (CSV). It contains no measured results or automatic acceptance.

Need evidence for a specific product?

Send the product, configuration and the document your project requires. We reply within one business day.

Get a quoteWhatsApp