ADA fiberglass grating: key facts
ADA fiberglass grating is FRP grating whose openings at the walking surface are small enough, no more than ½ in (13 mm), for an accessible route. F1's smallest-opening rows are the molded 13 × 13 mm mini mesh and the pultruded T-1210 and T-1215 T-bar series; the clear opening of the offered panel is confirmed before it is specified.
- The rule
- 2010 ADA Standards §302.3: openings in walking surfaces on an accessible route must not pass a ½ in (13 mm) sphere, with elongated openings perpendicular to the direction of travel.
- Molded option
- 13 × 13 / 40 × 40 mm mini mesh, 22, 30 and 40 mm deep, 30% open area, 15.0 to 25.0 kg/m² nominal.
- Pultruded option
- Wide-top T-bar series T-1210 and T-1215 at 12% open area; the T-bar tops leave narrow slots that run across the bearing bars.
- Heel-resistant
- The 19.05 × 19.05 mm mini mesh resists narrow heels but its top mesh is above the ADA ½ in limit.
- Verify
- Compliance belongs to the installed route: measure the clear opening of the offered panel and show the bar direction on the layout drawing.
What the ADA opening rule asks of a grating
The 2010 ADA Standards, section 302.3, limits openings in floor and ground surfaces on an accessible route: a sphere of ½ in (13 mm) diameter must not pass through, and elongated openings are laid with the long side across the main direction of travel so that wheels and cane tips do not drop in.
For grating this means two checks: the clear opening at the top surface, which depends on the bar width as well as the mesh, and the panel direction on the layout drawing. Industrial access codes use a different test, for example a 35 mm ball, or 20 mm where people work below, under EN ISO 14122-2.

Small-opening rows in the F1 catalog
| Type | Mesh or series | Depth | Open area | Weight | Opening check |
|---|---|---|---|---|---|
| Molded | 13 × 13 / 40 × 40 mm mini mesh | 22 | 30% | 15.0 | 13 mm nominal top mesh: measure the clear opening |
| Molded | 13 × 13 / 40 × 40 mm mini mesh | 30 | 30% | 19.0 | 13 mm nominal top mesh: measure the clear opening |
| Molded | 13 × 13 / 40 × 40 mm mini mesh | 40 | 30% | 25.0 | 13 mm nominal top mesh: measure the clear opening |
| Molded | 19.05 × 19.05 / 38.1 × 38.1 mm mini mesh | 25 | 30% | 16.8 | Top mesh above 13 mm: heel-resistant, check against the ADA limit |
| Molded | 19.05 × 19.05 / 38.1 × 38.1 mm mini mesh | 30 | 30% | 18.5 | Top mesh above 13 mm: heel-resistant, check against the ADA limit |
| Molded | 19.05 × 19.05 / 38.1 × 38.1 mm mini mesh | 38 | 30% | 23.5 | Top mesh above 13 mm: heel-resistant, check against the ADA limit |
| Pultruded | T-1210 T-bar | 25 | 12% | 14.5 | Bars at 43.4 mm centers: confirm the gap between T tops |
| Pultruded | T-1810 T-bar | 25 | 18% | 13.8 | Bars at 50.8 mm centers: confirm the gap between T tops |
| Pultruded | T-1215 T-bar | 38 | 12% | 19.6 | Bars at 43.3 mm centers: confirm the gap between T tops |
Full tables: molded FRP grating and FRP pultruded grating. Hold-downs for both: fiberglass grating clips.
How to verify a panel for an accessible route
- Check 1
Ask for the clear opening
Request the measured opening at the walking surface for the exact mesh or series, depth and surface finish, not only the mesh pitch.
- Check 2
Fix the direction
Mark the bearing-bar or long-opening direction on the panel layout so slots run across the route.
- Check 3
Check transitions
Keep changes in level at panel joints, landings and edges within the route's tolerance; grit surfaces add height.
- Check 4
Keep the evidence
File the opening data and the approved layout with the handover documents for the inspector.
Choosing between the two families: molded vs pultruded FRP grating. Stairs and platforms on the same route: FRP access platforms and stairs.
ADA grating questions
What does the ADA require for grating openings?
Section 302.3 of the 2010 ADA Standards says openings in floor or ground surfaces must not let a sphere more than ½ in (13 mm) in diameter pass, and elongated openings must run with their long dimension perpendicular to the dominant direction of travel. It applies to surfaces on an accessible route.
Is fiberglass grating ADA compliant?
A grating panel can satisfy the opening rule when its clear opening at the walking surface is no more than ½ in and it is laid in the right direction. Compliance is a property of the installed route, so measure the opening of the offered panel and check the orientation on the layout drawing; a mesh name alone is not proof.
Which F1 grating has the smallest openings?
The molded 13 × 13 / 40 × 40 mm mini mesh, in 22, 30 and 40 mm depths, and the pultruded T-1210 and T-1215 T-bar series at 12% open area. Request the clear-opening dimension for the exact panel before specifying it on an accessible route.
Is heel-proof grating the same as ADA grating?
Not necessarily. Heel-resistant grating has small enough openings to stop most narrow shoe heels catching, which a 19 mm mini mesh can do, but the ADA limit for an accessible route is ½ in (13 mm). Check which requirement the project actually needs.
Do small openings reduce drainage?
Yes. The small-opening rows listed here have 12% to 30% open area, while most standard industrial rows in the catalog run from about 40% up to 84%. Plan drainage, debris and cleaning with that in mind, especially outdoors.
Quote small-opening grating
Send the route layout, the accessibility rule it must meet, spans and loads, surface and the exposure. We confirm the clear opening of the offered panel with the quotation. We reply within one business day; a formal quotation follows once the specification and delivery are reviewed.
- Route
- Plan with the direction of travel, panel layout, landings and transitions.
- Rule
- ADA 2010 §302.3, a local accessibility code or a heel-resistance requirement.
- Structure
- Spans, supports, loads and deflection limit.
- Surface and site
- Grit or plain surface, outdoor exposure, drainage and cleaning.