Skip to content
Access structures

FRP access platforms, stairs and crossovers

Bolted fiberglass work platforms, crossovers, stair towers and walkways, built from pultruded profiles, grating, treads, handrails and ladders. Check the stair and walkway rules, then send a layout for a cut-and-drilled kit.

FIG. 1 Stair and platform, F1 factoryProject photo
FRP access staircase and platform with orange handrails inside F1 Composite's Chongqing plant
Structures
Platforms · crossovers · stairs
Joints
Bolted, no hot work
Stair codes
OSHA · ISO · AS · IBC
Supply
Marked kit to drawing

Last updated

FRP access platforms and stairs: key facts

FRP access platforms, crossovers and stairs are bolted fiberglass structures made from pultruded profiles, grating, stair treads, handrails and ladders. F1 Composite supplies the components cut and drilled to an approved drawing, with the section data the project engineer needs for the design check.

What they are
FRP access platforms, crossovers, stairs and walkways are bolted fiberglass structures assembled from pultruded profiles, grating, stair treads, handrails and ladders.
What F1 supplies
Catalog profiles, molded and pultruded grating, stair treads, handrail systems, fixed ladders and FRP fasteners, cut and drilled to an approved drawing and marked against a bill of materials.
Stair geometry
OSHA 1910.25 standard stairs: 30° to 50°, risers no more than 9.5 in (241 mm), treads at least 9.5 in. EN ISO 14122-3: 20° to 45° with g + 2h between 600 and 660 mm.
Walkway rules
EN ISO 14122-2: clear width at least 600 mm and 2,100 mm headroom. ASCE 7-22: 40 psf plus 300 lb for catwalks, 60 psf for elevated platforms.
Assembly
Bolted, with no welding or hot work. F1's own factory stair was assembled by four people with hand tools.
Design responsibility
The project engineer sizes members, connections and anchors under the governing code; F1 provides the section and laminate data for that check.

Five access structures, one set of components

  • Work platforms

    A deck at a fixed height beside equipment, valves or tanks: columns, beams, grating, handrail and toe board, reached by a stair or ladder.

    WF or square-tube columns · I-beam or channel framing · grating · handrail system

  • Crossovers

    A short stair up, a walkway across and a stair down, used to step over pipes, conveyors, trenches or cable runs instead of climbing over them.

    Channel stringers · stair treads · grating walkway · handrails both sides

  • Stairs and stair towers

    Straight flights between levels, or several flights with landings stacked in a tower where the height or footprint calls for it.

    I-beam or channel stringers · stair treads · landings in grating · stair rail and guardrail

  • Walkways and catwalks

    Long, narrow walking routes along process lines, roofs or tank tops, often on existing steel or concrete supports.

    Pultruded grating on I-beam or channel bearers · grating clips · edge guardrail

  • Fixed ladder access

    Vertical access where a stair does not fit, with a cage or ladder safety system as the code requires.

    FRP ladder rails and rungs · cage or safety system · platform landing

FIG. 2 Stringers and frameProject photo
Side view of FRP I-beam stringers and pultruded structural profiles forming the staircase frame inside F1 Composite's Chongqing factory
FIG. 3 Stair flight from belowProject photo
Underside of the stair flight: FRP I-beam stringers carrying the treads, with the orange FRP handrail alongside
FIG. 4 Beam-to-post connectionProject photo
Bolted connection between the platform beams and a post, all pultruded FRP profiles with stainless steel bolts

Photos from the F1 factory access staircase: I-beam stringers, pultruded posts, grating landings and an FRP handrail, bolted together without welding or a crane.

Which F1 product makes which part

Access structure elements and the F1 products used for them
ElementF1 product
Columns and postsWide flange (WF) beams · Square tubes
Beams, bearers and stringersI-beams · Channels
Bracing and bracketsAngles · Flat bars
Deck and landingsPultruded grating · Molded grating
Grating hold-downsGrating clips
Stair treadsFRP stair treads and covers
Edge protectionIndustrial handrail systems
Vertical accessFixed ladders
ConnectionsFRP bolts, nuts and threaded rod

Stair geometry by code

Requirement text from the access geometry checker, which applies the same rules to your riser, going, width and headroom.

OSHA 29 CFR 1910.25(c), standard stairs (US workplaces)

OSHA 29 CFR 1910.25(c), standard stairs (US workplaces) stair requirements
Angle30° to 50° from horizontal (1910.25(c)(1))
Riser heightNo more than 9.5 in (241 mm) (1910.25(c)(2))
Tread depthAt least 9.5 in (241 mm) (1910.25(c)(3))
WidthAt least 22 in (559 mm) between vertical barriers (1910.25(c)(4))
HeadroomAt least 6 ft 8 in (2,032 mm) above the tread nosing (1910.25(b))
Strength and uniformity5 × the normal live load and at least 1,000 lb (454 kg) at any point; risers and treads uniform within 1/4 in per flight (1910.25(b))

EN ISO 14122-3:2016, stairs for machinery access (EU/UK)

EN ISO 14122-3:2016, stairs for machinery access (EU/UK) stair requirements
Step formula g + 2h600 to 660 mm (EN ISO 14122-3:2016)
Angle20° to 45°; 30° to 38° preferred (EN ISO 14122-3:2016)
Clear widthAt least 600 mm; 800 mm recommended (EN ISO 14122-3:2016)
HeadroomAt least 2,300 mm (EN ISO 14122-3:2016)
Flight rise between landingsNo more than 3,000 mm (EN ISO 14122-3:2016)

AS 1657:2018, stairways for industrial access (AU/NZ)

AS 1657:2018, stairways for industrial access (AU/NZ) stair requirements
Angle20° to 45°; 30° to 38° preferred (AS 1657:2018)
Riser height130 to 225 mm (AS 1657:2018)
Going215 to 355 mm (AS 1657:2018)
Step formula 2R + G540 to 700 mm (AS 1657:2018)
Risers in one flightNo more than 18 risers between landings (AS 1657:2018)
HeadroomAt least 2,000 mm, more where hard hats are worn (AS 1657:2018)
Clear widthPublished summaries give at least 600 mm between stiles; confirm in the standard. Handrails on both sides above 1,000 mm width (AS 1657:2018)

IBC 2024 §1011, stairways in buildings (US)

IBC 2024 §1011, stairways in buildings (US) stair requirements
Riser height4 to 7 in (102–178 mm) (IBC 2024 §1011.5.2)
Tread depthAt least 11 in (279 mm) (IBC 2024 §1011.5.2)
HeadroomAt least 80 in (2,032 mm) (IBC 2024 §1011.3)
WidthAt least 44 in (1,118 mm), or 36 in (914 mm) where the occupant load is under 50 (IBC 2024 §1011.2)

Check a proposed stair, ladder or walkway with the access geometry checker; guardrail heights and loads are on the industrial handrail systems page, and ladder rules in the fixed ladder requirements guide.

Floor loads for platforms and walkways

Reference values the grating and framing are designed for. The code in force for the project governs.
Reference floor loads for walkways and platforms
RuleUseLoad
ASCE 7-22 Table 4.3-1 (US)Catwalks for maintenance and service access40 psf (1.92 kPa) and 300 lb (1.33 kN) concentrated
ASCE 7-22 Table 4.3-1 (US)Walkways and elevated platforms other than exitways60 psf (2.87 kPa)
OSHA 29 CFR 1910.22(b) (US)Every walking-working surfaceIts maximum intended load; no fixed value
EN ISO 14122-2:2016 (EU/UK)Working platforms and walkways2 kN/m² on the structure; 1.5 kN on 200 × 200 mm on the flooring; deflection no more than span/200 and 4 mm step to the adjacent unloaded panel
AS/NZS 1170.1 and AS 1657:2018 (AU/NZ)Walkways and platformsTake the values for the occupancy from the standard; AS 1657 walkways are at least 600 mm wide with 2,000 mm headroom
NBC Part 4 (Canada)Service rooms, catwalks and platformsEnter the value from Table 4.1.5.3 of the code in force

Choosing the deck: molded vs pultruded grating and the FRP grating selector. Sizing columns: FRP column calculator.

From layout to a marked, bolted kit

  1. Step 1

    Layout and levels

    Plan and section with the deck level, obstacles to clear, stair start and landing points, and existing supports.

  2. Step 2

    Code and loads

    The stair, guardrail and floor-load rules the project uses, plus equipment, wind or maintenance loads.

  3. Step 3

    Member check and drawing

    Members, connections and bases are sized by the project engineer; F1 supplies section and laminate data for the check.

  4. Step 4

    Marked kit

    Profiles cut and drilled to the approved drawing, grating cut to the panel plan, every part marked against the BOM.

  5. Step 5

    Bolted assembly

    Assembly with bolts and hand tools on site; anchors and the supporting structure are by others unless agreed.

Chemical and wastewater sites: FRP chemical plant platforms. Comparing materials: FRP vs steel, aluminum and timber and the life-cycle cost calculator.

Access platform and stair questions

What is an FRP crossover?

An FRP crossover is a small fiberglass structure with a stair or ladder on each side and a short walkway between them, built so people step over pipes, conveyors, trenches or cable runs. It is assembled from pultruded profiles, grating, stair treads and handrails and bolted together.

Can FRP stairs and platforms meet OSHA requirements?

They can be designed to a stated rule such as OSHA 1910.25 for stairs, 1910.29 for guardrails and 1910.22 for walking surfaces. Compliance belongs to the finished structure: geometry, members, connections and anchors checked by the project engineer, not to a material or a catalog part.

Are fiberglass platforms welded?

No. Pultruded FRP is a thermoset and is not welded; platforms are bolted, with FRP or stainless steel fasteners. That is why an FRP access structure can be assembled without hot work, which matters on many chemical and energy sites.

What load can an FRP platform carry?

As much as it is designed for. The floor load comes from the governing rule, for example 40 psf with a 300 lb concentrated load for catwalks or 60 psf for elevated platforms under ASCE 7-22, and the members, grating and connections are sized for it. F1 does not publish a single rating for an access structure.

Does F1 design the platform?

F1 supplies the profiles, grating, treads, handrails, ladders and fasteners, with section and laminate data, and cuts and drills them to an approved drawing. Structural design and approval stay with the project engineer unless an engineering scope is agreed in the quotation.

How does an FRP platform compare with steel or aluminum?

Compare complete structures designed for the same loads and geometry. FRP does not rust and is non-conductive in many exposures, and the parts are light to handle; steel and aluminum are stiffer per section. The material comparison page and the life-cycle calculator help set up a fair comparison.

Quote an FRP platform, stair or crossover

Send a plan and section with levels, the obstacle to clear, the stair or ladder positions, the code and loads, and the site exposure. Existing drawings or photos help. We reply within one business day; a formal quotation follows once the specification and delivery are reviewed.

Layout
Plan, section, deck level, stair start and landing points, obstacles and existing supports.
Code and loads
Stair, guardrail and floor-load rules, equipment and maintenance loads.
Scope
Components only, a cut-and-drilled kit, or a kit with agreed engineering support.
Site
Chemicals, outdoor exposure, fire requirements, anchors and delivery destination.
Get a quoteWhatsApp